Error flow chart
9
Inspect the rail connection part of the gear rack
on the drawer side.
≥
Use the UD guide check fixture to check the gaps in all
rail connection parts of the gear rack.
≥
Rail check: pattern 1
1
Release the connection of the gear
rack. (
2
Remove the M5 screws from the two modules.
3
Open the module halfway and pull out.
4
Redo the tasks starting from
Gap under 1.5 mm (0.06
q
)
Use the washers supplied with the Bottom
Module to readjust the front and back of the
module and perform the installation (
32) so
that the gap becomes under 1.5 mm (0.06
q
) .
If there was an error in checks in patterns
1 to 3 (gaps of 1.5 mm (0.06
q
) or more)
OK
Error
ACCEPT
UD guide check fixture
Use these parts.
Gap under 1.0 mm (0.04
q
)
Put the fixture in the rail connection part
of the gear rack on the drawer side, then
slide from right to left to check.
Under 1.0 mm
(0.04
q
)
1.0 mm (0.04
q
) or more
Refer to the
following "Error
flow chart".
OK
Error