background image

2

3

 Caution 

:  Failure to follow these instructions may 

cause a risk of personal property damage.

Do not step on or drop any hard article down 

on top plate.

If it is cracked or broken up, it may cause overheating, 
abnormal operation or electric shock.

Do not touch top plate or other heating parts 

when the unit is running.

It may cause burn.

Use heat resistant materials for the 

countertop.

The material of the countertop should have heat-

 

q

resistancy equal to or exceeding “laminated 

thermosetting high-pressure decorative sheets”.

If the materials are not heat resistant, it may cause 
deformation or fire.

* Do not use varnished materials as they might be 

discolored.

 Warning 

:  Failure to follow these instructions may 

cause a risk of personal injury or death.

Follow these instructions when installing the 

unit.

If it is installed improperly, it may cause electric 
leakage or overheat.

Install a dedicated circuit of single phase 

220V/20A with a breaker for power supply.

If dedicated circuit is not connected compatibly, it may 
cause abnormal heat on electric wires.

Electrical work should be done by a qualified 

electrician.

If the connection or repair is not completed, it may 
cause electric leakage or overheat.

Never disassemble, repair or modify the unit.

Any attempt to do so may cause the unit to operate 
abnormally and may result in danger.

Install the ground completely with related law.

Installation of ground can avoid electric shock once 
electric leakage occurs.

The ground should be installed by a qualified 

electrician.

If the installation is not proper, electric leakage may 
occur.

If the supply cord is damaged, it must be 

replaced by the manufacturer or its service 

agent or related qualified electrician in order 

to avoid a hazard.

Safety precautions for installation

1

Please observe these precautions fully

Dimensions

2

(measurement: mm)

Top view

Side view

749

Exhaust vent

450

250

184

380

200

200

Intake vent 

(2 places on the undersurface)

వઈϾ

כઈϾ)ϭব3഍*

12

411

17

Intake vent

כઈϾ

Exhaust vent

వઈϾ

Cord length: approx. 1.5m

 

q

Front view

715

96

108

安裝時的安全防護措施

 注意事項 

: 表示如不避免,則可能導致輕微或

中度傷害的某種潛在危害情況。

切勿踩踏面板或使硬物墜於其上。

如果面板破裂或斷裂,會導致過熱或操作異常,甚至
造成漏電。

切勿在本機工作時,觸摸面板及其他發熱部位。

避免灼傷或意外。

操作台請使用耐熱材料。 

因 該 使 用 與“ 熱 固 性 樹 脂 浸 漬 紙 高 壓 裝 飾 層 積 板

q

q

(HPL)”相同或更好的耐熱材料。

如果使用非耐熱材料,則可能會導致變形,甚至引發
火災。

*

q切勿使用塗漆材料,否則可能會造成褪色。

 警告 

表示如不避免,則可能導致死亡或
嚴重傷害的某種潛在危害情況。

請按照此說明安裝本機。

如果安裝不正確,可能會導致漏電或變得過熱。

請安裝單相220V/20A的專用電路保護器電路。

如果專用電路安裝不當,可能會導致電線異常發熱。

電氣工程應由合資格的電氣技工施工。

如果連接和維修工作未完成,則可能會導致漏電或變
得過熱。

切勿試圖自行拆卸、維修,或改裝本機。

任何這方面的嘗試,都可導致本機操作異常,引起危
險。

請依據相關規定正確安裝地線。

安裝地線可避免在漏電時觸電。

安裝地線應由合資格的電氣技工施工

如果安裝不當,可能會引致漏電。

如果附帶的電線有破損,則必須經原廠或代理商以
及有相關資格的電氣技工來更換,以免發生危險。

請完全遵守下述防護措施

尺寸

(單位:mm)

頂視圖

側視圖

電線長度:約 1.5m

q

q

正視圖

Содержание KY-E227B

Страница 1: ... free standing or built in Keep this instruction Be sure to entrust a qualified gas technicians or a personnel from gas company q q close a gas valve when replacing the gas appliances with this unit Install the unit in accordance with the Installation Instructions Otherwise it may q q affect performance of the product Any malfunction or accident etc resulting from failure to follow Installation q ...

Страница 2: ...sassemble repair or modify the unit Any attempt to do so may cause the unit to operate abnormally and may result in danger Install the ground completely with related law Installation of ground can avoid electric shock once electric leakage occurs The ground should be installed by a qualified electrician If the installation is not proper electric leakage may occur If the supply cord is damaged it m...

Страница 3: ...ust be separated 1cm or above as there is an exhaust vent at the backside of the unit ӎᑟߞࢢൊգవઈϾȂ ԯऎ ᛓӅ Դ2 dn或以上Ȅ In case surrounding wall is combustible w w non fire protection construction wall 若周圍是易燃材料的牆壁 w w 無防火結構的牆 built in 嵌入式 free standing 座檯式 Combustible ceiling 100 cm or above ݽ ᑼߞчࠅ ޕ 211 dn 或以上 Combustible wall ݽ ᑼߞᖒᐨ 6 dn 或以上 5 cm or above Combustible wall ݽ ᑼߞᖒᐨ 6 dn 或以上 5 cm or above ...

Страница 4: ...disconnection in case of emergency q q Electrical work should be done by a qualified electrician Installation dedicated circuit Installation electric leakage breaker Install dedicated circuit of single phase w w 220V 20A with a breaker on power supply Use the following interior electric cable w w Wall socket box type More than 2 0mm wire diameter or more than 3 5mm2 stranded wire Flush mounted soc...

Страница 5: ...09 ZY16H8741 F0909I1102 Printed in Japan Make sure to turn the main power switch off after w w electric testing Please hand operating instructions installation w w instructions and Guarantee certificate to the customer I hereby certify that installation has been completed Signature of installer Before installation cut along perforation to take off a serial number seal that is on the backside of th...

Отзывы: