Electrical Work

 

Electrical requirements

 

Electrical connections

 - This appliance must be supplied with the proper voltage and frequency, and 

connected to an individual, properly grounded branch circuit, protected by a 

circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)

 - Means for disconnection must be incorporated in the fixed wiring in 

accordance with the wiring rules.

 - You must use a three-wire, single-phase A.C. 240 V, 40 A, 60 Hz electrical 

system. If you connect to aluminum wiring, properly use connectors 

approved for use with aluminum wiring.

 - Check with the local utilities for electrical codes applied in the area. 

Failure to wire the appliance according to governing codes may result in 

a hazardous condition. If there are no local codes, the appliance must be 

wired and fused to meet the requirements of CSA and CEC.

 - After installation, show the customer where the breaker for the appliance is located.

1. Turn off power.

Turn off power at the circuit breaker or remove fuses to the appliance 

branch circuit.

2. Connect the power cord.

Connect the power cord in accordance with all governing codes and 

ordinances.

WARNING

Electrical work must be 

performed by a legally 

qualified electrician.

E L2 L1

Connect 

to the 

ground 

terminal.

Connect 

to the line 

terminal.

Yellow / Green

Black

Red

CAUTION

For your safety, remove 

the plastic cover from 

the power cord before 

performing electrical work.

 - In accordance with the electrical wiring rules, incorporate the earth leakage 

circuit breaker in the home electrical wire.

 - Follow the specification of the earth leakage circuit breaker as follows. 

  Rated current: 40 A, rated sensitivity current: 30 mA

 

Installation of the earth leakage circuit breaker

2. Embed the main unit in the countertop cutout 

while keeping it is as level as possible.

 - Do not drop the unit on the countertop.

 - Press down on top of the main unit to make sure 

that the frame is solidly rest on the countertop.

 - Make sure that the spaces between the 

countertop and the under surface of the top 

frame are even in the front, back, left and right.

Installing the Appliance

Correct

Incorrect

WARNING

Do not disassemble the top plate. 

Connected wire may become loose 

and cause a malfunction.

CAUTION

If the cabinet does not have an 

opening in the front, the wiring needs 

to be connected before the main unit 

is embedded into the countertop.

1. Fasten the clamps to the main unit  

(4 places on the front and back).

 - Put the Cardboard A underneath the main unit to act 

as a buffer in order to prevent the countertop from 

getting damaged.

 - Match the clamp grips with the holes on the sides of 

the main unit, then slide the clamp from the right to 

the left to fasten them to the main unit.

Cardboard A 

3. Connect the power cord

See page 8.

Содержание KY-B84AX

Страница 1: ...llation Location 4 Accessories 4 Dimensions 5 Related Dimensional Drawings for Custom Kitchens 6 Electrical Work 8 Installing the Appliance 9 Post installation Checklist 10 Installation Instructions Induction Heating Cooktop Model No KY B84AX KY B84AG ENGLISH ...

Страница 2: ...pliance in accordance with the Installation Instructions Otherwise the performance of the appliance may be affected Make sure to perform a test run and explain to the customer how to properly use the appliance Proper installation is the responsibility of the installer Any malfunction or accident resulting from the failure to follow Installation Instructions is not covered under guarantee Hand thes...

Страница 3: ...allation Location Observe the laws concerning the installation of the appliance 4 pieces For more details on cutout see page 6 Clamp Intake vent Exhaust vent Cooking zone Min 51 mm clearance from cutout to rear wall Max 330 mm depth of cabinets Min 51 mm clearance from cutout to side wall Cutout Min 762 mm clearance from the top of the cooktop to the bottom of the cabinets Dimensions 83 74 57 723 ...

Страница 4: ...tertop front Min 59 Building side wall Building rear wall Min 30 for flat part Bulge of front countertop Rear side Front side Intake Shelf Exhaust Min 300 for vertical clearance Flow of intake and exhaust Min 170 Min 51 Min 600 Min 51 Min 51 Allow for a minimum of 95 mm extra space between the countertop and the top surface of the oven for air circulation Rear side Front side Exhaust Flow of intak...

Страница 5: ... line terminal Yellow Green Black Red CAUTION For your safety remove the plastic cover from the power cord before performing electrical work In accordance with the electrical wiring rules incorporate the earth leakage circuit breaker in the home electrical wire Follow the specification of the earth leakage circuit breaker as follows Rated current 40 A rated sensitivity current 30 mA Installation o...

Страница 6: ...e earth leakage circuit breaker been installed Electrical testing 1 Touch to turn on the main power Does the main power light light up 2 Touch the following keys to check function of each IH heater Left front heater Left rear heater Right front heater Right rear heater Make sure to turn off each IH heater and the main power switch after performing electrical testing Hand the Operating Instructions...

Отзывы: