background image

2

3

WARNING:

 Failure to follow these instructions may cause 

death or serious injury.

 - When performing the installation, follow these instructions 

properly. 

Improper installation may cause an electric leakage or 

fire.

 - Install 240 V / 40 A dedicated single phase circuit with the 

earth leakage circuit breaker for the power supply. 

The 

electrical wiring may abnormally overheat if the dedicated circuit is 

not properly connected.

 - Electrical work must be performed by a legally qualified 

electrician. 

Improper wire connections may cause electric 

leakages or fires.

 - Ground the appliance following the electric laws. 

Failure to do 

so may cause electric shock due to electric leakages.

CAUTION:

 Failure to follow these instructions may cause 

injury or property damage.

 - Use heat resistant materials for the countertop. However, do 

not use varnished materials as they might get discolored.  

The material of the countertop should have heat resistancy equal 

to or exceeding “laminated thermosetting high-pressure decorative 

sheets”. If the materials are not heat resistant, they may get 

deformed or cause a fire.

Please fully observe the following safety precautions.

IMPORTANT

 - Install the appliance in accordance with the Installation 

Instructions. Otherwise, the performance of the appliance 

may be affected.

 - Make sure to perform a test run and explain to the customer 

how to properly use the appliance.

 - Proper installation is the responsibility of the installer. Any 

malfunction or accident resulting from the failure to follow 

Installation Instructions is not covered under guarantee.

 - Hand these Installation Instructions to the customer for the 

local electrical inspector’s use.

 - Have a qualified electrician ground the appliance. 

Improper 

grounding may cause an electric shock.

 - Before performing the installation, definitely turn off the 

circuit breaker. 

This can prevent electric shock.

 - The power cord must be accurately connected to ensure the 

integrity of the connection. 

Improper wire connections may 

cause electric leakages or fires.

 - If the power cord is damaged, it must be replaced by the 

manufacturer or its service agent or a similar qualified person in 

order to avoid a hazard.

 - Do not disassemble, repair or modify the appliance (the 

top plate, for example). 

Doing so may cause the appliance to 

operate abnormally and may result in danger.

 - Do not step on the appliance, or drop heavy items on top of 

it. 

Cracks in the top plate may cause overheating, malfunctions or 

electric shocks.

 - Do not touch high temperature parts, such as the top plate.

Safety Precautions

Содержание KY-B84AX

Страница 1: ...llation Location 4 Accessories 4 Dimensions 5 Related Dimensional Drawings for Custom Kitchens 6 Electrical Work 8 Installing the Appliance 9 Post installation Checklist 10 Installation Instructions Induction Heating Cooktop Model No KY B84AX KY B84AG ENGLISH ...

Страница 2: ...pliance in accordance with the Installation Instructions Otherwise the performance of the appliance may be affected Make sure to perform a test run and explain to the customer how to properly use the appliance Proper installation is the responsibility of the installer Any malfunction or accident resulting from the failure to follow Installation Instructions is not covered under guarantee Hand thes...

Страница 3: ...allation Location Observe the laws concerning the installation of the appliance 4 pieces For more details on cutout see page 6 Clamp Intake vent Exhaust vent Cooking zone Min 51 mm clearance from cutout to rear wall Max 330 mm depth of cabinets Min 51 mm clearance from cutout to side wall Cutout Min 762 mm clearance from the top of the cooktop to the bottom of the cabinets Dimensions 83 74 57 723 ...

Страница 4: ...tertop front Min 59 Building side wall Building rear wall Min 30 for flat part Bulge of front countertop Rear side Front side Intake Shelf Exhaust Min 300 for vertical clearance Flow of intake and exhaust Min 170 Min 51 Min 600 Min 51 Min 51 Allow for a minimum of 95 mm extra space between the countertop and the top surface of the oven for air circulation Rear side Front side Exhaust Flow of intak...

Страница 5: ... line terminal Yellow Green Black Red CAUTION For your safety remove the plastic cover from the power cord before performing electrical work In accordance with the electrical wiring rules incorporate the earth leakage circuit breaker in the home electrical wire Follow the specification of the earth leakage circuit breaker as follows Rated current 40 A rated sensitivity current 30 mA Installation o...

Страница 6: ...e earth leakage circuit breaker been installed Electrical testing 1 Touch to turn on the main power Does the main power light light up 2 Touch the following keys to check function of each IH heater Left front heater Left rear heater Right front heater Right rear heater Make sure to turn off each IH heater and the main power switch after performing electrical testing Hand the Operating Instructions...