Note:
DSP is IC201.
See
CPU DATA (BASE UNIT)
()
You can enable or disable the Auto Disconnect function.
See
Check Record
().
17.8. Parallel Connection Detect Circuit
Function:
In order to disable call waiting and stutter tone functions when using telephones connected in
parallel, it is necessary to have a circuit that judges whether a telephone connected in parallel is
in use or not. This circuit determines whether the telephone connected in parallel is on hook or
off hook by detecting changes in the T/R voltage.
It is like an “Auto Disconnect Circuit”.
Circuit Operation:
Parallel connection detection when on hook:
When the set is on hook, the voltage is monitored at DSP (DCIN0). There is no parallel connection
if the voltage is 2.50 V or higher, while a parallel connection is deemed to exist if the voltage is
lower.
Parallel connection detection when off hook:
When the set is off hook, the voltage is monitored at DSP (DCIN1); the presence/absence of a
parallel connection is determined when the voltage changes by 0.2 V or more.
17.9. Calling Line Identification (Caller ID)/Call Waiting Caller ID
Function:
Caller ID
The caller ID is a chargeable ID which the user of a telephone circuit obtains by entering a
contract with the telephone company to utilize a caller ID service. For this reason, the operation
of this circuit assumes that a caller ID service contract has been entered for the circuit being
used.
The data for the caller ID from the telephone exchange is sent during the interval between the
first and second rings of the bell signal. The data from the telephone exchange is a modem signal
59
Содержание KXTG2226W - 2.4GHZ DIGITAL PHONE
Страница 6: ...4 5 Battery Replacement 4 6 Battery information 5 LOCATION OF CONTROLS 5 1 Base Unit 6 ...
Страница 7: ...5 2 Handset 7 ...
Страница 8: ...6 DISPLAY 6 1 Troubleshooting 8 ...
Страница 9: ...9 ...
Страница 10: ...10 ...
Страница 11: ...11 ...
Страница 12: ...12 ...
Страница 14: ...7 2 Downloading Phone Book Data 14 ...
Страница 15: ...15 ...
Страница 16: ...7 3 Information Download Handset 16 ...
Страница 17: ...8 SETTINGS 8 1 Connections 8 2 Display Language 17 ...
Страница 18: ...8 3 Dialing Mode Handset 8 4 Direct Commands 18 ...
Страница 19: ...9 OPERATIONS 9 1 Making Calls Handset 19 ...
Страница 20: ...20 ...
Страница 21: ...21 ...
Страница 22: ...9 2 Answering Calls Handset 9 3 FLASH Button Handset 22 ...
Страница 23: ...9 4 Erasing Messages 23 ...
Страница 25: ...25 ...
Страница 26: ...9 5 2 Dialing from the Phone Book Handset 26 ...
Страница 27: ...9 5 3 Editing an Item in the Phone Book Handset 27 ...
Страница 28: ...9 5 4 Erasing an Item in the Phone Book Handset 10 DISASSEMBLY INSTRUCTIONS 28 ...
Страница 31: ...11 ASSEMBLY INSTRUCTIONS 11 1 Fix the LCD to P C Board Handset 12 TROUBLESHOOTING GUIDE 31 ...
Страница 37: ...12 6 Check Link 37 ...
Страница 45: ...12 8 Check Handset Transmission Cross Reference SIGNAL ROUTE 45 ...
Страница 48: ...13 3 Test mode flow chart for Handset 48 ...
Страница 53: ...COMMUNICATION 15 1 Calling 15 2 To Terminate Communication 15 3 Ringing 53 ...
Страница 64: ...20 SIGNAL ROUTE Each signal route is as follows 64 ...
Страница 65: ...21 CPU DATA BASE UNIT 21 1 IC201 65 ...
Страница 66: ...22 CPU DATA HANDSET 22 1 IC201 66 ...
Страница 67: ...23 EXPLANATION OF RF UNIT TERMINALS 23 1 IC801 67 ...
Страница 68: ...68 ...
Страница 71: ...26 CABINET AND ELECTRICAL PARTS HANDSET 71 ...
Страница 72: ...27 ACCESSORIES AND PACKING MATERIALS 72 ...
Страница 73: ...28 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 28 1 Base Unit 28 2 Handset 73 ...
Страница 75: ...29 1 Base Unit 29 1 1 Cabinet and Electrical Parts 75 ...
Страница 90: ...18 1 1 30 PbF IC201 CN101 CN100 30 51 50 1 Marked ...
Страница 92: ...LCD900 1 12 MSG1 REG CHK ANS1 ANS2 ERS STOP REP SKIP DOWN UP ICON PbF MIC MSG2 Marked ...