37
KX-WT115CE
11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
Troubleshooting Guide
(P.25)
11.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
11.2. The Setting Method of JIG
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which has “FlashProgram.exe”
11.2.1. Connections (Handset)
Connect the DC Power or Battery to BATT+ and BATT-.
Connect the JIG cable GND (black) to GND.
Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX.
Note:
*: COM port names may vary depending on what your PC calls it.
Содержание KX-WT115CE
Страница 12: ...12 KX WT115CE 4 5 Signal Route RF part signal route ...
Страница 13: ...13 KX WT115CE 5 Location of Controls and Components 5 1 Handset ...
Страница 17: ...17 KX WT115CE 7 5 Display ...
Страница 19: ...19 KX WT115CE 7 8 Character Mode Table 7 9 For Service Hint ...
Страница 20: ...20 KX WT115CE 8 Service Mode 8 1 Key Operation ...
Страница 23: ...23 KX WT115CE For Service Use How to clear a handset s registration information ...
Страница 27: ...27 KX WT115CE 9 1 3 Check Link 9 1 3 1 Handset ...
Страница 34: ...34 KX WT115CE 10 Disassembly and Assembly Instructions 10 1 Disassembly Instructions 10 1 1 Handset ...
Страница 35: ...35 KX WT115CE 10 1 2 Charger Unit ...
Страница 60: ...60 KX WT115CE 15 2 Cabinet and Electrical Parts Charger Unit ...
Страница 61: ...61 KX WT115CE 15 3 Accessories and Packing Materials ...