    (*) Adjacency status color means condition that many CSs are gathering around the colored CS. 

 

Adjacency status color definition

 

 

 

Color

 

 

Condition

 

 

Solution

 

Green

 

Distance of each CS around the colored CS is suitable.

 

No need 

Yellow

 

Distance of each CS around the colored CS is close a 
little.

 

Move each CS around the 
colored CS away a little. 

Red

 

Distance of each CS around the colored CS is too close.

 

Move each CS around the 
colored CS further away.

 

 
 
8.  

Reset warning message is displayed. 

 

   

Click 

[OK]

 to continue. 

 

 

Содержание KX-UDS124

Страница 1: ...n 1 2 Thank you for purchasing this Panasonic product Please read this manual carefully before using this product and save this manual for future use SIP CS Maintenance Tool Software Version 1 0 2 0 o...

Страница 2: ...ed Add System is Rese ing operation as Step8 Change Step8 to Step9 Add an operation to return to the table view in step1 Add Description column in error log sample Change Additional language selection...

Страница 3: ...CS MAINTENANCE TOOL 4 3 1 INSTALLATION PROCEDURE 4 3 2 UNINSTALLATION PROCEDURE 7 4 OPERATING INSTRUCTIONS 8 4 1 STARTING THE CS MAINTENANCE TOOL 8 4 2 CONDUCTING THE TREE SURVEY 9 4 2 1 Tree Survey E...

Страница 4: ...T MAKE OR PASS ON TO YOU OR OTHER THIRD PARTY ANY WARRANTY OR REPRESENTATION INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITHOUT LIMITIN...

Страница 5: ...Guide describes about the installation maintenance and management of the SIP CS Manuals and supporting information are provided on the Panasonic Web site at http www panasonic com sip for users in th...

Страница 6: ...nce Tool requires the following login ID and password Account ID default Password default Password Restrictions Administrator admin adminpass You can change the password see Administrator Guide 2 4 2...

Страница 7: ...l 3 1 Installation Procedure Follow the procedure below to install the SIP CS Maintenance Tool on your PC 1 Copy the setup file of the SIP CS Maintenance Tool to your PC 2 Double click the setup file...

Страница 8: ...5 4 Check I accept the terms in the license agreement check box and click Next button 5 Click Next button to install in the default folder or click Change button to specify the destination folder...

Страница 9: ...6 6 Click Install button to start installation 7 Click Finish button to finish installation...

Страница 10: ...the procedure below to Uninstall the SIP CS Maintenance Tool on your PC 1 Select SIP CS Maintenance Tool program from the programs and features menu of Windows 2 Click Yes button to remove 3 Click Fi...

Страница 11: ...aight cable 2 Start the CS Maintenance Tool from the Start menu The login window is displayed 3 Enter an IP address of the Super Master CS and enter user name and password of administrator account You...

Страница 12: ...e Survey The tree survey can be conducted by the following procedure 1 Ensure that the Air Synchronization tab is selected 2 Select Air Sync Group No 1 8 that you want to conduct 3 Click Tree Survey t...

Страница 13: ...10 4 Select CSs for Tree Survey and Click Start 5 Tree Survey is executed...

Страница 14: ...n error message or notice message is displayed please refer to the 4 2 1 7 When the tree survey is complete the result and air synchronization tree are displayed If the tree survey was completed corre...

Страница 15: ...Green Distance of each CS around the colored CS is suitable No need Yellow Distance of each CS around the colored CS is close a little Move each CS around the colored CS away a little Red Distance of...

Страница 16: ...13 9 You can change view to previous tree format by clicking Tree Structure button...

Страница 17: ...e Cause Solution Notice Sync Slave CS does not have Secondary CS One or more SIP CSs could not have a Slave CS assigned for reasons such as avoiding the creation of a loop However this is not a proble...

Страница 18: ...g procedure 1 Ensure that the CS Status Monitor tab is selected 2 Select Air Sync Group No 1 8 that you want to monitor 3 From the Interval Timer drop down list select the desired interval time for mo...

Страница 19: ...ate Wired LAN status of each CS by mouseover action Click Table to view the status in a table Note The color of each CS indicates the worst status of RSSI or Error Rate 7 Click Stop to end monitoring...

Страница 20: ...Out of synchronization Wired LAN The wired LAN linkage status displayed in OK or NG CS Type Current air sync status Primary Synchronizing to primary setting CS Secondary Synchronizing to secondary set...

Страница 21: ...isplayed click Table 2 Click the Log button of each CS that you want to acquire 3 Enter command number that you want to acquire log type Command Log classification Contents Capacity CS 100 Error Detec...

Страница 22: ...CS fields 05 26 12 42 11 30006 Request sync signal to other CS fields 05 26 12 42 11 30007 Established Air sync to other CS 05 26 12 42 11 30007 Established Air sync to other CS 05 26 14 23 51 30006...

Страница 23: ...o select pre installed English select Pre Installed language radio button For other languages additional language xml files may be found at the Panasonic s website To use a language xml file select Ad...

Страница 24: ...apan Copyright This material is copyrighted by Panasonic System Networks Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written...

Отзывы: