37
KX-TG8041RU/KX-TGA800RU
(
G
)* BBIC Clock Adjustment
CLK
VDD4
1. Input Command “ sendchar WWD ff 48 IC 8006”
2. Confirm that the voltage between testpoint VDD4 and GND is less than 1.0 V.
3. Input Command “ sendchar sfr”, then you can confirm the current value.
4. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
5. If the frequency is not 10.368MHz ± 100Hz, adjust the frequency of CLK exe-
cuting the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
X1, IC7, C66
(
H
)* Hookswitch Check with
DC Characteristics
-
1. Connect Telephone Socket to Tel-simulator which is connected with 600
Ω
.
2. Set line voltage to 48 V and line current to 40mA at off-hook condition of nor-
mal telephone.
3. Execute the command “hookoff”
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
L1, L2, Q3, R14,
R15, Q4, R16,
R17, D3,
R18~R24,
C15~C17
,
D21,
Q5, R27, IC7
(
I
) DTMF Generator Check
-
1. Connect Telephone Socket to DTMF tester. (Load=600
Ω
)
2. Link Handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -3 ± 2dBm.
5. Confirm that the low Group is -6 ± 2dBm.
IC7, R25, C21,
R29, C22, C23,
D21
(
J
)* Transmitted Power Con-
firmation
-
ANTI_TP
Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: FP
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
2. Execute the command ”sendchar TST”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT1”.
7. Confirm that the NTP value at ANT is 19.0 dBm ~ 25.0 dBm.
IC7, L104,
C101, C106,
C102, C109,
R65, R66, DA1,
R802~R807,
C837, C826,
C822, C820,
C832, C833,
C63, Q401,
C402, C105,
C110, C65,
IC801, D801,
D802,
C801~C804,
C808~C814,
L802~L804,
C819, C834,
C825
(
K
)* Modulation Check and
Adjustment
-
ANTI_TP
Follow steps 1 to 6 of
(J)
.
7.Confirm that the B-Field Modulation is -370 ± 30/ +370± 30 kHz/div & Modu-
lated width 690 kHz using data type Fig31.
8.Adjust the B-Field Modulation if required. (Execute the command “readmod”
and “wrtmod xx”, where xx is the value.)
IC7, L104,
C101, C106,
C102, C109,
R65, R66, DA1,
R802~R807,
C837, C826,
C822, C820,
C832, C833,
C63, Q401,
C402, C105,
C110, C65,
IC801, D801,
D802,
C801~C804,
C808~C814,
L802~L804,
C819, C834,
C825
Items
Check
Point
Procedure
Check or
Replace Parts
Содержание KX-TG8041RUM
Страница 2: ...2 KX TG8041RU KX TGA800RU ...
Страница 14: ...14 KX TG8041RU KX TGA800RU 4 6 Signal Route ...
Страница 15: ...15 KX TG8041RU KX TGA800RU ...
Страница 17: ...17 KX TG8041RU KX TGA800RU 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Страница 19: ...19 KX TG8041RU KX TGA800RU 8 1 2 Handset ...
Страница 28: ...28 KX TG8041RU KX TGA800RU Cross Reference Check Point Base Unit P 36 ...
Страница 30: ...30 KX TG8041RU KX TGA800RU Cross Reference Check Point Handset P 40 ...
Страница 45: ...45 KX TG8041RU KX TGA800RU ...
Страница 46: ...46 KX TG8041RU KX TGA800RU 10 1 2 Handset ...
Страница 47: ...47 KX TG8041RU KX TGA800RU 10 1 3 Charger Unit ...
Страница 48: ...48 KX TG8041RU KX TGA800RU 10 2 How to Replace the Handset LCD ...
Страница 82: ...82 KX TG8041RU KX TGA800RU 15 3 Cabinet and Electrical Parts Charger Unit ...
Страница 83: ...83 KX TG8041RU KX TGA800RU 15 4 Accessories and Packing Materials 15 4 1 KX TG8041RUM RUT ...
Страница 84: ...84 KX TG8041RU KX TGA800RU 15 4 2 KX TGA800RUT RUC RUS ...