58
KX-TG6671B/KX-TG6672B/KX-TGA660B
12.5. Adjustment Standard (Portable)
When connecting the simulator equipment for checking, please refer to below.
12.5.1. Component View
Note:
(*1) is referred to No.2 of Check
Check Table for RF part
(P.40)
(*2) is referred to
Power Supply Circuit/Reset Circuit
(P.19)
KX-TGA660
A
PNLB1885
PbF
-PA
Blue
WLED
SP-PHONE
RECEIVER
Orange
GND
VBAT
UTX
URX
MIC-
SPP
MIC+
SPM
CD
CS
RESET
SCL
SID
VBAT_MON
VBG/CHG_MON
4.0V
3.0V
VDDC
CKM/STM
ATSTP
ATSTN
TEST
RSTN
E_SCL
E_SDA
E_WP
CHG_DET
CHG_CTRL
VREF
CHG_CUR
GND_J
TDO
TCK
TMS
TDI
X1
BATT+
BATT-
CHG(+)
CHG(-)
CHG(+)
CHG(-)
IC4
orange
green
IC1
IC3
blue
orange
C13
C11
C96 C86
C12
C73
C37
C6
C97
C34
C41
C51
C32
C29
DA801
C21
C30
C20
C31
C44
C811
L809
C18
C40
C17
C98
C138
C188
C26
C505
C24
C23
C814
C806
C810
C812
C813
C805
C820
C896
C859
C822
C172
C10
C65 C64
C2
C1
C150
C56
C5
C147
C74
CN4
C113
C185
C83
C80
C110
C108
1
5
4
3
2
C58
C49
R24
R22
R33
R66
R807
R3
R9
R8
R6
L9
L71
IC6
RA3
D4
Q4
Q9
Q6
C70
C504
C71
C152
C72
C14
C36
C33
C183
C45
C43
C46
C826
C863
C25
C22
C184
C16
C127
C9
C8
C99
C81
C77
C76
C825
C897
C895
C7
C78
C84
C79
C121
C75
C15
C48
C57
C3
F1
2.5A
C4
C50
C19
C82
R501
R19
R27
R28
R34
R20
R25
R26
R7
R1
R504
ANT_TP
ANT-Short
ANT-Short-GND
R806
R509
R561
R23
R31
R64
R32
R68
R69
R67
R21
R563
R562
R4
R2
R74
R73
R45
R308
R306
L14
L29
L13
L73
L74
L72
L6
RA4
RA5
RA2
D22
D21
D14
D13
D3
D1
Q5
Q2
Q3
150
40
Oscilloscope
Oscilloscope
VOLT METER
VOLT METER
MIC Load
MIC+ +
+
MIC-
GND
VBAT
47
47
Spectrum Analyzer
Connect between ANT-Short and ANT-Short GND.
ANT
DC VOLT METER
DC POWER SUPPLY
2.6 V 2.34 V
OSC
1.1 kHz
Frequency Counter (*1)
Oscilloscope (*2)
* Send command "SFR", then
the frequency output on this TP.
* Start Monitor
CKM/STM