57
KX-TG6551CAM/KX-TGA650RUM/KX-TGA651RUM
11.5. The Setting Method of JIG (Handset)
This section explains the PC setting to use command required in
Check Point (Handset)(
P.44).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
•
Batch file CD-ROM
for setting: PNZZTG6551CA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.5.1. Connections
Connect the DC Power or Battery to BATT+ and BATT-.
Connect the JIG cable GND (black) to GND.
Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω
)
New value (k
Ω
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
1
2
3
DC Power
or Battery
2
GND (black)
3
To Serial Port
(com port 1*)
JIG Cable
PC
UTX (yellow)
3
URX (red)
Handset P. C. board
1
BATT-
BATT+
GND
UTX
URX