13
KX-TG6551CAM/KX-TGA650RUM/KX-TGA651RUM
4.3.5.
Parallel Connection Detect Circuit
Function:
In order to disable call waiting and stutter tone functions when using telephones connected in parallel, it is necessary to have a
circuit that judges whether a telephone connected in parallel is in use or not. This circuit determines whether the telephone
connected in parallel is on hook or off hook by detecting changes in the T/R voltage.
Circuit Operation:
Parallel connection detection when on hook:
When on hook, the voltage is monitored at pin 17 of IC501. There is no parallel connection if the voltage is
0.54 V or higher, while a parallel connection is deemed to exist if the voltage is lower.
Parallel connection detection when off hook:
When off hook, the voltage is monitored at pin 18 of IC501; the presence/absence of a parallel connection is determined by
detecting the voltage changes.
If the Auto disconnect function is ON and statuses are Hold, receiving ICM, OGM transmitting, BBIC disconnects the line after
detecting parallel connection is off hook.
Q141
Q161
R141
R142
Q142
R117
R115
R116
19 pin
IC501 DCIN 3
IC501 DCIN 1 17 pin
R118
R151
R145
Pin 18 of IC501
DCIN2
HOOK
Pin 6 of IC501
C101
D101
C102
SA101
P101
TEL JACK
3
4
2
1
R163
R167
L1T
L1R
R152
C152
RA151