34
KX-TG4771B/KX-TG4772B/KX-TG4773B/KX-TGA470B
10.1.3. Check Playback
10.1.3.1. Base Unit
Cross Reference:
Power Supply Circuit/Reset Circuit
(P.12)
Note:
Flash Memory is IC601.
BBIC is IC1.
(*1) Refer to
Base Unit (Main)
(P.75).
10.1.4. Check Battery Charge
10.1.4.1. Portable
Cross Reference:
Check Power
(P.30)
Charge Circuit
(P.19)
10.1.4.2. Charger Unit
Cross Reference:
Charge Circuit
(P.19)
5) Back to "standby" mode automatically after step 4).
You can hear beep sound which is a confirmation tone.
Note:
(*1) Both Auto Disconnect and CPC don't detect for the first 2 seconds.
(*2) If the "Disable" is selected, e
v
en if the parallel-connected telephone is OFF HOOK,
the line isn't disconnected.
Is BBIC (IC1: 34) high at charge state?
Check
Charge Circuit
.
Check
Power
of Portable.
Is
Check Power
OK?
NO
NO
YES
Check
Charge Circuit
of Charger Unit.
Check Portable.
Plug in the AC Power source.
Charge Portable on Charger Unit.
Is the voltage of two charge contacts about
3 V or more?
OK
NO
Check Charge Contacts at Charger Unit
from mechanical point of view.
YES
Содержание KX-TG4771B
Страница 65: ...65 KX TG4771B KX TG4772B KX TG4773B KX TGA470B Memo ...
Страница 72: ...72 KX TG4771B KX TG4772B KX TG4773B KX TGA470B 14 6 Portable LED LED KX TGA470 SCHEMATIC DIAGRAM Handset LED ...
Страница 74: ...74 KX TG4771B KX TG4772B KX TG4773B KX TGA470B Memo ...
Страница 80: ...80 KX TG4771B KX TG4772B KX TG4773B KX TGA470B Memo ...