62
KX-TGE240/242/243/244/245/260/262/263/264/270/272/273/274/275/TG454/TG465/TGEA20/TGA20
12.5.1.2. Handset
First, operate the PC setting according to
Then download the appropriate data according to the following procedures.
Note:
(*3) XXX_YYY: revision number
"XXX_YYY" vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in
Items
How to download/Required adjustment
BBIC(IC1)
Programming data is stored in memory.
1) System Clock adjustment.
EEPROM (IC3)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Default batch file: Execute the command “default.bat”.
2) Default batch file (remaining): Execute the command
“TGEA20_US_DEF_RevXXX_YYY.bat”. (*3)
3) Country version batch file: Execute the command
“TGEA20_US_US_RevXXX_YYY.bat”. (*3)
4) System Clock adjustment
5) 2.35 V setting and battery low detection
X'tal (X1)
System clock
1) Apply 2.6V between BATT+ and BATT- with DC power.
2) Input Command " sendchar sfr", then you can confirm the
current value.
3) Check X'tal Frequency.(13.824 MHz ± 100 Hz).
4) If the frequency is not 13.824 MHz ± 100 Hz, adjust the fre-
quency of CLK executing the command "sendchar sfr xx xx
(where xx is the value)" so that the reading of the frequency
counter is 13.824000 MHz ± 5 Hz.
Содержание KX-TG454SK
Страница 70: ...70 KX TGE240 242 243 244 245 260 262 263 264 270 272 273 274 275 TG454 TG465 TGEA20 TGA20 Memo ...
Страница 84: ...84 KX TGE240 242 243 244 245 260 262 263 264 270 272 273 274 275 TG454 TG465 TGEA20 TGA20 Memo ...
Страница 88: ...88 KX TGE240 242 243 244 245 260 262 263 264 270 272 273 274 275 TG454 TG465 TGEA20 TGA20 Memo ...
Страница 90: ...90 KX TGE240 242 243 244 245 260 262 263 264 270 272 273 274 275 TG454 TG465 TGEA20 TGA20 Memo ...