36
KX-TG4111MEB/KX-TG4112MEB/KX-TGA410MEB
10.1.4.2. RF Check Flowchart
Each item (1 ~ 5) of RF Check Flowchart corresponds to
Check Table for RF part
(P.37).
Please refer to the each item.
Note:
(*1) Refer to
Check Link
(P.33).
Start
Link
confirmation
Normal
1
Control
signal
confirmation
X'tal
Frequency
confirmation
TX confirmation
Range
confirmation
Normal
TEST RANGE Check.
Check BBIC interface parts.
(RF Block <->BBIC on BU/HS P.C.B)
Adjust X'tal Frequency. (*1)
Check TX Block.
GOOD
5
2
3
4
OK
OK
OK
NG
NG
NG
NG
NG
OK
OK