53
KX-TG3411BX/KX-TG3412BX/KX-TG3419BX/KX-TGA341BX
12.8. Things to Do after Replacing IC or X'tal
If repairing or replacing EEPROM
or X'tal, it is necessary to download the required data such as Programming data or adjustment
data, etc. in memory.
The set doesn't operate if it is not executed.
12.8.1. How to download the data
12.8.1.1. Base Unit
First, operate the PC setting according to
The Setting Method of JIG
(P.44).
Then download the appropriate data according to the following procedures.
Note:
(*1) W: country code, XXX_YYY: revision number
"W", "XXX_YYY"
vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in
The Setting
Method of JIG
(P.44).
Items
How to download/Required adjustment
EEPROM (IC611)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “55” to download
the data.
2) Default batch file: Execute the command “default.bat”.
3) Country version batch file: Execute the command
“TG3411_W_RevXXX_YYY.bat.bat”. (*1)
4) Bandgap voltage & frequency adjustment: Refer to
Adjustment of Base Unit
(P.48)
.
X'tal (X501)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Frequency adjustment: Refer to
Adjustment of Base Unit
(P.48)
.