8.2.1. Preparation
8.2. The Setting Method of JIG (Base Unit)
8.2.1.1. Equipment Required
•
•
•
•
DECT tester: Rohde & Schwarz, CMD 60 is recommended.
•
•
•
•
Frequency counter: it must be precise to be able to measure 1Hz (precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
•
•
•
•
DC power: it must be able to output at least 1A current under 9V.
•
•
•
•
Digital multi-meter (DMM): it must be able to measure voltage and current.
•
•
•
•
Oscilloscope
8.2.1.2. JIGs and PC
•
•
•
•
EEPROM serial JIGs
1. I2C PCB: PQZZTCD420BX
2. RS232C cable: PQZZ1CD705BX
3. Clip cable: PQZZ2CD705BX
4. DC cable: PQZZ3CD705BX
•
•
•
•
PC which runs in DOS mode
•
•
•
•
Batch file CD-ROM
for setting: PQZZTG1105RU
8.2.2. PC Setting
8.2.2.1. Connections
Connect the AC adaptor to J2 (base unit).
Connect the RS232C cable to the Serial Port of PC.
Connect the DC cable to the DC Power.
Connect the Clip cable GND.
Connect the Clip cable SCL and SDA.
Note:
*: Com port names may vary depending on what your PC calls it.