3.2 Installation of the PBX
52
Installation Manual
3.2.4
Installing/Replacing the Power Supply Unit
Function
Accessories and User-supplied Items
Accessories (included):
Screws × 4, AC power cord × 1
User-supplied (not included):
Grounding wire
Notes
•
For details about frame ground connection, refer to "3.2.5 Frame ground Connection".
Safety Instructions
Each PSU complies with Safety Class 1 of IEC60950, EN60950, UL60950,
CAN/CSA-C22.2 No.60950, and AS/NZS60950; therefore a protective ground connection exists between
the mains outlet ground and the PSU case. To ensure the PBX chassis is safely grounded, it is essential
that the PSU case be securely fastened to the PBX chassis with the 4 screws provided with each PSU.
When installing or replacing a PSU, basic safety precautions should always be followed to reduce the risk
of fire, electric shock and injury to persons, including the following:
1.
Never install or replace a PSU during a lightning storm.
2.
Never install or replace a PSU in wet locations.
3.
Never install or replace a PSU unless at least 20 s has elapsed after the AC supply is disconnected.
PSU Type
Lower/Upper Input Voltage Range
Current
Input Frequency
PSU-S
(for KX-TDE100)
Lower: 100 V AC to 130 V AC
1.4 A
50 Hz or 60 Hz
Upper: 200 V AC to 240 V AC
0.8 A
PSU-M
(for KX-TDE100/KX-
TDE200)
Lower: 100 V AC to 130 V AC
2.5 A
Upper: 200 V AC to 240 V AC
1.4 A
PSU-L
(for KX-TDE200)
Lower: 100 V AC to 130 V AC
5.1 A
Upper: 200 V AC to 240 V AC
2.55 A
AC Inlet
Power Switch
AC Inlet
Power Switch
PSU-S
PSU-M/PSU-L
Ground Terminal
Ground Terminal
Содержание KX-TDE110
Страница 38: ...1 4 Specifications 38 Installation Manual ...
Страница 44: ...2 1 Information about the Activation Keys 44 Installation Manual ...
Страница 166: ...3 14 Starting the PBX 166 Installation Manual ...
Страница 186: ...5 1 Troubleshooting 186 Installation Manual ...
Страница 187: ...Installation Manual 187 Index ...
Страница 191: ...Index Installation Manual 191 ...