4.2 PC Connection
170
Installation Manual
IMPORTANT
To protect the system, keep the following in mind:
1.
Make sure that both connector cases (frame ground) of the RS-232C cross cable (shielded
cable) are conductive. If they are not conductive, make sure that both connector cases of
the cable are firmly connected.
2.
If this is not possible, connect the frame of the PBX to the frame of the PC using an earthing
wire in order to prevent difference in the electrical potentials.
Note
For pin assignments and maximum cabling distance, refer to "3.11.1 Connection of Peripherals".
External Modem Connection
IMPORTANT
To protect the system, keep the following in mind:
1.
Make sure that both connector cases (frame ground) of the RS-232C straight cable
(shielded cable) are conductive. If they are not conductive, make sure that both connector
cases of the cable are firmly connected.
2.
If this is not possible, connect the frame of the PBX to the frame of the external modem
using an earthing wire in order to prevent difference in the electrical potentials.
After connecting the PBX and the external modem, set the power switch of the external modem to "ON",
then the external modem will be initialized with the default values.
The following AT command settings may be required for the modem:
Modem
To RS-232C port (25-pin)
To CO line/PBX extension port
assigned as the CO line destination
RS-232C Port
(9-pin)
External Modem (25-pin)
PBX (9-pin)
Signal Name
RD (RXD)
SD (TXD)
ER (DTR)
DR (DSR)
Signal Name
RD (RXD)
SD (TXD)
ER (DTR)
DR (DSR)
Pin No.
2
3
4
6
Pin No.
3
2
20
6
Содержание KX-TDE110
Страница 38: ...1 4 Specifications 38 Installation Manual ...
Страница 44: ...2 1 Information about the Activation Keys 44 Installation Manual ...
Страница 166: ...3 14 Starting the PBX 166 Installation Manual ...
Страница 186: ...5 1 Troubleshooting 186 Installation Manual ...
Страница 187: ...Installation Manual 187 Index ...
Страница 191: ...Index Installation Manual 191 ...