2.8 [1] Configuration
PC Programming Manual
87
Value Range
8 × n (n=3–255) ms
Maintenance Console Location
2.8.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Manual References
None
SLT Off Hook Guard Time
Specifies the length of guard time used for off-hook signals from SLTs, to prevent the PBX mistaking
them for pulse dials.
Default
504 ms
Value Range
8 × n (n=12–63) ms
Maintenance Console Location
2.8.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Manual References
None
SLT Pulse Maximum Break Width
Specifies the maximum length of the break signal in a pulse dial.
Default
96 ms
Value Range
8 × n (n=9–20) ms
Maintenance Console Location
2.8.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None