2.8 [1] Configuration
PC Programming Manual
179
Value Range
None, 16 × n (n=1–255) ms
Maintenance Console Location
2.8.17 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
1.5.1 EFA (External Feature Access)
Disconnect Time
Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize the
line.
Default
1.5 s
Value Range
0.5 s, 1.5 s, 2.0 s, 4.0 s, 12.0 s
Maintenance Console Location
2.8.17 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
1.6.2 Flash/Recall/Terminate
2.8.18 [1-1] Slot—Port Property - T1 Port—Connection Command
(KX-TDA100/KX-TDA200/KX-TDA600 only)
Commands for the T1 channels can be programmed.
INS
Puts the channel in service.
Default
Not applicable.
Value Range
Not applicable.