2.6 Connection of Extensions
84
Installation Manual
2.6.3
Digital EXtra Device Port (Digital XDP) Connection
A DPT can be connected to another DPT on the Digital XDP connection. In addition, if the DPT is connected
to a Super Hybrid Port, it can also have an SLT connected in Parallel mode or XDP mode.
Notes
•
Both DPTs must be KX-T7600 series DPTs (excluding KX-T7640).
•
Parallel mode or XDP mode can be selected through system programming.
With KX-T7600 Series DPT
Using a Modular T-Adaptor
To DLC4/DLC8 card
To a Super Hybrid Port
(for connection of SLT)
4-conductor wiring cord
Connect pins "D1" and "D2".
Slave DPT
SLT
Master DPT
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and
"D2".
2-conductor wiring cord
Connect pins "T" and "R".
Slave DPT
Master DPT
TO MAIN UNIT
/ PABX
TO TEL
TO MAIN UNIT
/ PABX
Cable
Maximum Distance
26 AWG: 30 m (98 ft)
24 AWG: 50 m (164 ft)
22 AWG: 60 m (196 ft)
CAT 5:
50 m (164 ft)
Back View of DPTs
To DLC4/DLC8 card
To a Super Hybrid Port
(for connection of SLT)