1.14.1.2 Conference
Description
An extension user can establish a conference call by adding additional parties to an already existing two-party
conversation. This PBX supports three-party through eight-party conference calls. Conferences with more than
four parties are only possible when a PT or PS user originates the conference.
Unattended Conference:
The conference originator can leave the conference and allow other parties to continue. Establishing an
Unattended Conference allows the originator to return to the conference. Unattended Conferences can only
be established by PT and PS users.
Conditions
•
When an extension is establishing a conference call the original party is put on hold.
•
CONF (Conference) Button
For a PT/PS which does not have the CONF button, a flexible button can be customised as the Conference
button.
•
Unattended Conference Call Duration
The length of time that a conference call can remain unattended is restricted by the following timers:
–
Callback Start Timer
–
Warning Tone Start Timer
–
Disconnect Timer
These timers behave and operate according to the following chain of events:
1.
When the unattended conference is established, the Callback Start Timer will begin.
2.
When the Callback Start timer expires, the Unattended Conference originator’s extension will start to
receive a callback ringing from the PBX and the Warning Tone Start Timer begins.
3.
When the Warning Tone Start Timer expires, the remaining parties of the conference will start to hear
a warning tone, the callback ringing will continue to be heard at the Unattended Conference
originator’s extension, and the Disconnect Timer begins.
4.
When the disconnect Timer expires, the conference is disconnected.
If the Unattended Conference originator returns to the conference before the line is disconnected, all timers
are cleared
•
For a Conference With Six or More Parties
The ECHO card is required. Also the echo cancelling function should be enabled through system
programming.
Installation Manual References
2.6.5 ECHO16 Card (KX-TDA0166)
PC Programming Manual References
4.4 [2-3] Timers & Counters—DISA / Door / Reminder / U. Conf
Unattended Conference—Recall Start Timer
Unattended Conference—Warning Tone Start Timer
Unattended Conference—Disconnect Timer
4.11 [2-7-1] Class of Service—COS Settings—CO & SMDR—
4.17 [2-9] System Options—Option 3
Confirmation Tone—Tone 4-1 : Start Conference
Confirmation Tone—Tone 4-2 : Finish Conference
Feature Guide
175
1.14.1 Conference Features
Содержание KX-TDA100D
Страница 7: ...VPS Voice Processing System X XDP EXtra Device Port Feature Guide 7 List of Abbreviations ...
Страница 13: ...Section 1 Call Handling Features Feature Guide 13 ...
Страница 35: ...PT Programming Manual References 720 Doorphone Call Destination Feature Guide 35 1 1 2 Internal Call Features ...
Страница 89: ...User Manual References 1 2 1 Basic Calling Feature Guide 89 1 5 4 Trunk Call Features ...
Страница 121: ...User Manual References 1 2 4 When the Dialled Line is Busy or There is No Answer Feature Guide 121 1 8 3 Call Monitor ...
Страница 154: ...Feature Guide References 1 20 2 Flexible Buttons 154 Feature Guide 1 11 6 Flash Recall Terminate ...
Страница 156: ...User Manual References 1 10 4 If a Host PBX is Connected 156 Feature Guide 1 11 7 External Feature Access EFA ...
Страница 168: ...User Manual References 1 4 2 Holding a Call 168 Feature Guide 1 13 1 Call Hold ...
Страница 367: ...Section 2 System Configuration and Administration Features Feature Guide 367 ...
Страница 409: ...Section 3 Appendix Feature Guide 409 ...
Страница 414: ...Item Capacity User Level Programmer Code 0 16 characters 414 Feature Guide 3 1 Capacity of System Resources ...
Страница 417: ...Index Feature Guide 417 ...
Страница 423: ...Feature Guide 423 Notes ...