4.3 Configuring Domain Name System (DNS) Data

Getting Started

27

4.3

Configuring Domain Name System (DNS) 
Data

The function of a DNS in a VoIP network is to provide telephone number-to-IP Address 
translations

*1

. The IP Gateway Card has internal DNS database capabilities that can contain a 

maximum of 511 units in the network. DNS database is owned jointly by all units in the network 
(therefore it is necessary to update every unit with the latest DNS database whenever the 
network configuration is changed).

For example numbering plan, refer to 1.2 Network Devices and Numbering Plan.

4.3.1

Editing DNS Data

*1

IP address-to-telephone number translation can also be handled by using an H.323 Gatekeeper device. To configure 
Gatekeeper devices, refer to the manufacturer's documentation. This manual focuses on the method using the KX-
TDA0480 internal DNS capabilities.

1.

a.

Highlight "

Main

" in the Groups Window 

Pane.

b.

Select "

Tools

"  

"

DNS (static transfer)

 "

Edit

".

2.

"Configure DNS setting" window appears. 
Click [Add].

3.

a.

Enter 

Terminal number

Remaining 

digits

, and 

Comment

.

b.

Select the desired unit(s), then click [OK].

Configuration example of Los Angels 
telephone extensions (200-299):
• PBX Office Code: 35
• Telephone extension starting digit: 2
• Remaining digits: 2 (i.e., 00-99)

Содержание KX-TDA0480

Страница 1: ...A0480 IP Gateway Card Getting Started Thank you for purchasing the Panasonic Model KX TDA0480 IP Gateway Card Please read this manual before installing the IP Gateway Card and save this manual for fut...

Страница 2: ...19 4 1 The Maintenance Console Software MCS 20 4 1 1 Installing the MCS 20 4 1 2 Starting MCS and Logging in 21 4 1 3 MCS Main Directory Window 21 4 1 4 Serial Port Setting 22 4 1 5 Changing the Pass...

Страница 3: ...DA0480 designed to be easily integrated into existing LAN WAN environments seamlessly bridges Public Switched Telephone Network PSTN and analogue telephone with digital data networks without interrupt...

Страница 4: ...y Card converts outgoing voice or fax signals into IP data packets for transmission On the incoming side it reverses this process and translates the packets back into appropriate voice or fax signals...

Страница 5: ...obtain necessary information to configure your own network PSTN Public Switched Telephone Network LAN Chicago Office PBX Office Code 41 Gateway Unit IP 199 176 64 41 IP Trunk number 801 PSTN Local Tel...

Страница 6: ...ple diagramme Please configure your network referring to this example IP Addressing Information IP addressing information is typically supplied by a network administrator Consult your network administ...

Страница 7: ...Office PBX Office Code A unique number ranging from 1 to 8 digits assigned to identify each Hybrid IP PBX within a network In this example for convenience each PBX Office Code corresponds to the last...

Страница 8: ...al Port Number The TCP port number on which call control signal transmission will occur When installing the IP Gateway Card within a firewall as in this example voice and fax packets must routed throu...

Страница 9: ...Getting Started 9 Section 2 Physical Installation...

Страница 10: ...h Settings The default DIP Switch settings are as illustrated below Confirm that the switches are in the default positions before installing the IP Gateway Card Indication Lights LED1 IP Link Connecto...

Страница 11: ...1 Insert the card along the guide rails 2 Holding the card as shown on the left push the release lever in the direction of the arrow so that the card is made to engage with the connector on the back...

Страница 12: ...de LED3 Red Alarm Off Normal On Alarm LED4 Green Busy status Off Not used On At least one line is used LED5 Green Link status Off Connection error On Normal Connection LED6 Green Data transmission Off...

Страница 13: ...evice 1 Insert the RJ 45 connector into the IP Gateway Card Uplink port located on the IP Gateway Card front panel 2 Connect the other end of the 10 Base T cable to the remote LAN equipment When conne...

Страница 14: ...2 2 Cable Connection 14 Getting Started...

Страница 15: ...Getting Started 15 Section 3 Trunk Programming of the Hybrid IP PBX...

Страница 16: ...IP PBX follow the procedure below Note It is assumed that you have already installed the PC Programming Software in your PC 1 Double click TDA PC Programming icon 2 Type the password then click OK to...

Страница 17: ...of the Hybrid IP PBX Getting Started 17 7 Enter CO Name max 20 characters and Trunk Group Number 01 64 for the desired Trunk CO Number then click OK to enable the setting 8 Select Connect Disconnect...

Страница 18: ...3 1 Trunk Programming of the Hybrid IP PBX 18 Getting Started...

Страница 19: ...nsole Software This section describes the logical installation process involving the following operations 1 create New Groups and Gateway units 2 configure common DNS Data 3 configure unit specific Of...

Страница 20: ...Programming Guide System Requirements Microsoft Windows 95 Windows 98 or Windows NT 4 0 or later Minimum requirements for installing Maintenance Console Software only CPU Pentium MHz RAM MB HDD MB Tra...

Страница 21: ...he installation is complete 3 icons will be created 1 Double click IVG MCS icon Initial screen appears 2 Type mcs default password then click OK to log in To change the default password see 4 1 5 Chan...

Страница 22: ...f a port other than COM 1 is used to connect the IP Gateway Card and the computer the MCS serial communications parameter must be reconfigured 1 Select Tools Options 2 Select Serial port of the PC tha...

Страница 23: ...Console Software MCS Getting Started 23 4 1 5 Changing the Password 1 Select Tools Options 2 a Click the Password tab b Enter the Current password c Enter and confrim the New password then click OK to...

Страница 24: ...New Unit Group Office 4 2 2 Creating a New Gateway IP Gateway Card Each newly installed IP Gateway Card must first be initialized with its new IP addressing To perform the following operation the RS 2...

Страница 25: ...6 Enter IP Address Subnet Mask and Route Address of the Gateway then click Next Consult your network administrator for specific values 4 Setup Wizard 3 6 Enter Call control signal TCP port no default...

Страница 26: ...rd user then click Next Enter and confirm the User Level Password to change the default password then click Next 7 Setup Wizard 6 6 Select Option 2 and RS232C as the Reboot access mothod then click Fi...

Страница 27: ...ring plan refer to 1 2 Network Devices and Numbering Plan 4 3 1 Editing DNS Data 1 IP address to telephone number translation can also be handled by using an H 323 Gatekeeper device To configure Gatek...

Страница 28: ...creates the database for entire network as a simple text file named DNS DAT in the Ccons12 System subdirectory N 352 R2 I 200 45 11 35 1720 N 355 R2 I 200 45 11 35 1720 N 359 R7 I 200 45 11 35 1720 N...

Страница 29: ...n which it is installed The MCS permits all configuration file data to be entered and edited while off line In the procedures discussed in this section the completed configuration files will be upload...

Страница 30: ...Data 30 Getting Started Numbering Office Code Setting Hunt Pattern Setting Trunk Data a Click the Numbering tab b Enter Office Code then click OK a Click the Hunt pattern tab b Click OK a Click the Tr...

Страница 31: ...TDA0480 of IP Gateway Card Installation Manual Trunk priority Voice mode Network Call Control SNMP Recovery delay Notify e mail Priority routing information a Click the FAX related tab b Select TCP d...

Страница 32: ...ard in the network Notes To transfer data using the following procedure the Gateway parameters must have been previously uploaded Refer to 4 2 2 Creating a New Gateway IP Gateway Card for details When...

Страница 33: ...from a power source for more than two months causing the battery discharge However the alarm indications do not affect the IP Gateway Card operations they should be corrected following the procedure...

Страница 34: ...4 6 Synchronising Time and Date of the IP Gateway Card 34 Getting Started...

Страница 35: ...Getting Started 35 Section 5 Optimising Performance...

Страница 36: ...out from the unit settings Indications that some adjustment is required are Voice level too low Increase gain by decreasing PAD level Voice loud distorted Decrease gain by increasing PAD level Excess...

Страница 37: ...ompensate for network congestion problems To configure please refer to 4 9 1 Configure Gateway Units KX TDA0480 of IP Gateway Card Installation Manual 5 1 5 Internet Intranet and Virtual Private Netwo...

Страница 38: ...he essential requirements of the Directive 1999 5 EC Radio and telecommunications terminal equipment directive This manual is copyrighted by Kyushu Matsushita Electric Co Ltd KME You may print out thi...

Отзывы: