Items
Adjustment
Point
Procedure*
Check or
Replace Parts
(
H
)* BBIC Clock Adjusment
TP19
1. Execute the command "conttx".
2. Adjust the frequency of TP19 executing thecommand "setfreq 00 xx (where xx
is the value)" so that the reading of the frequency counter is 10.368000MHz ±
3Hz.
IC1,L3,C57,
IC3,X1,C16,
C17
(
I
)*
Transmitted Power
Confirmation
TP15
Remove the Antenna before starting step from 1 to 5.
1. Configure the DECT tester(CMD60) as follows;
<Setting>
·
Test mode: PP
·
RFPI: 0102030405
·
Traffic Channel: 5
·
Traffic Slot: 4
·
Mode: Loopback
2. Execute the command "testmode".
3. Execute the command "regcmd60"
4. Initiate connection from DECT tester.
5. Confirm that the NTP value at A201 (TP15) is 20dBm ~ 25dBm
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
R18
(
J
) Modulatoin Check and
Adjusment
TP15
Follow steps 1 to 4 of
(I)
above.
5. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/div using data
type Fig31.
6. Adjust the B-Field Modulation if required. (Execute the command "Readmod"
and "Writemod xx", where xx is the value.)
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
R18
(
K
)
Frequency Offset
Confirmation
-
Follow steps 1 to 4 of
(I)
above.
5. Confirm that the frequency offset is < ± 40kHz.
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
R18
(
L
)
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 4 of
(I)
above.
5. Set DECT tester power to -88dBm.
6. Confirm that the BER is < 1000ppm.
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
R18
(
M
)
Timing Confirmation
-
Follow steps 1 to 4 of
(I)
above.
5. Confirm that the Timing accuracy is < ± 10ppm.
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
R18
(
N
)*
RSSI Level
Confirmation
-
Follow steps 1 to 4 of
(I)
above.
5. Set DECT tester power to -88dBm.
6. Execute the command "readrssi"
7. Confirm that the returned value is 0x34 ± A (hex).
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
R18
43
KX-TCD400RUB / KX-TCD400RUC / KX-TCD400RUF / KX-A140RUB / KX-A140RUC / KX-A140RUF