7.2. How to change the channel
Note:
Refer to Adjustment Standard (Base Unit) (P.21) for connection.
7.3. Adjustment
Adjustment Items Test Mode
Adjustment
Point
*Procedure
Check or
Replace
Parts
(A) RX VCO
Adjustment
3ch Talk
T404
•
Adjust T404 so that the reading of the Digital Voltmeter is 1.5 ± 0.3 V.
IC401, T404,
C446
(B) TX VCO
Adjustment
3ch Talk
T402
•
Adjust T402 so that the reading of the Digital Voltmeter is 1.5 ± 0.3 V.
IC401,
DV401,
T402
(C) TX Frequency
Confirmation
3ch Talk
-
•
Confirm so that the reading of the frequency counter is 43.82MHz ±
700Hz.
IC401, X401,
DV401,
C440,
C441
(D) TX Power
Adjustment
3ch Talk
T403
•
Adjust T403 so that the reading of the RF VTVM is more than 10dBm.
IC401, Q403,
Q405, T403,
DPX401
(E) RX Sensitivity
Confirmation (2nd
IF output)
3ch Talk
T401
1.
Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.
0KHz).
2.
Confirm that the reading of AF VTVM is the maximum value (more than
20mV).
DPX401,
T401,
CF401,
CF402
(F) Line Output Level
Confirmation
3ch Talk
-
1.
Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.
3KHz).
2.
Confirm that the reading of AF VTVM is more than 150mV (600
Ω
load).
IC401, Q304
(G) Line Input
Modulation
Confirmation
3ch Talk
-
1.
Input via loop simulator 1.0KHz, 55mV (measured at T-R) signal.
2.
Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.
0KHz).
3.
Confirm so that the reading of FM Deviation Meter is 2.7 ± 0.5KHz.
IC401,
DV401
(H) Noise Squelch
Confirmation
3ch Talk
-
1.
Measure the S.S.G. output level when the noise squelch changes from
Low to High.
2.
Confirm that the S.S.G. output level is -95dBm ~ -100dBm.
IC401,
DPX401
* : The connections of adjustment equipment are as shown in Adjustment Standard (Base Unit) (P.21).
S.S.G. Frequency: 49.86 MHz
20
KX-TC2101BXB
Содержание KX-TC2101BXB
Страница 7: ...4 2 Location of Controls 4 2 1 Base Unit 4 2 2 Handset 7 KX TC2101BXB ...
Страница 8: ...4 3 Connection 8 KX TC2101BXB ...
Страница 9: ...4 4 Troubleshooting 9 KX TC2101BXB ...
Страница 18: ...Cross Reference SIGNAL ROUTE P 41 6 6 Check Handset Reception 18 KX TC2101BXB ...
Страница 28: ...12 2 Ringing 28 KX TC2101BXB ...
Страница 29: ...12 3 Changing the Channel 29 KX TC2101BXB ...
Страница 41: ...17 SIGNAL ROUTE Each signal route is as follows 41 KX TC2101BXB ...
Страница 42: ...18 CPU DATA Base Unit 18 1 IC201 42 KX TC2101BXB ...
Страница 43: ...19 CPU DATA Handset 19 1 IC701 43 KX TC2101BXB ...
Страница 44: ...20 RF IC Base Unit and Handset 20 1 Base Unit IC401 Handset IC801 44 KX TC2101BXB ...
Страница 47: ...22 CABINET AND ELECTRICAL PARTS BASE UNIT 47 KX TC2101BXB ...
Страница 48: ...23 CABINET AND ELECTRICAL PARTS HANDSET 48 KX TC2101BXB ...
Страница 49: ...24 ACCESSORIES AND PACKING MATERIALS 49 KX TC2101BXB ...
Страница 50: ...25 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 25 1 Base Unit 25 2 Handset 50 KX TC2101BXB ...
Страница 58: ...Memo KX TC2101BXB 58 ...
Страница 63: ...63 KX TC2101BXB A I N KXTC2101BXB ...