![Panasonic KX- TAW848 Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/panasonic/kx-taw848/kx-taw848_installation-manual_263246081.webp)
2.7 Connection of 2.4 GHz Portable Stations
Installation Manual
81
2.7.7 Connecting a Cell Station to the PBX
Refer to the following example to connect a CS to the PBX.
Accessory and User-supplied Items for the CS
Accessory (included):
Screws
×
2, Washers
×
2
User-supplied (not included):
RJ11 connector
Note
For details about HLC4 card, refer to "2.4.1 HLC4 Card".
A Hybrid Port or HLC4 card (RJ11)
CS (RJ11)
Cable
Maximum Distance
26 AWG:
Under 222 m (728 ft)
24 AWG:
Under 347 m (1138 ft)
22 AWG:
Under 500 m (1640 ft)
CAT 5:
Under 347 m (1138 ft)
Signal Name
Signal Name
Pin No.
1
2
3
4
D1
D2
D1
D2
Pin No.
1
2
3
4
Hybrid Port