2.2 Installing the Advanced Hybrid System
34
Installation Manual
2.2.7
Installing Surge Protector
Overview
A massive electrical surge can be caused if lightning strikes a telephone cable 10 m (33 ft) above
ground, or if a telephone line comes into contact with a power line. A surge protector is a device that
is connected to an outside (CO) line to prevent potentially dangerous electrical surges from entering
the building via the outside (CO) lines and damaging the PBX and connected equipment.
To protect the PBX from electrical surges, we strongly recommend connecting the PBX to a surge
protector that meets the following specifications:
–
Surge arrestor type: 3-electrode arrestor
–
DC spark-over voltage: 230 V
–
Maximum peak current: at least 10 kA
Additionally, proper grounding is very important for the protection of the PBX. (
Many countries/areas have regulations requiring surge protection. Be sure to comply with all
applicable laws, regulations, and guidelines.
Installation
Extn.
Surge
Protector
Outside
(CO) Line
Terminal
Board
Outside
(CO) Line
PBX
Outside
(CO) Line
Extn.
Ground
Extn.
Frame Ground
SLT
PT
Extn.: Extension Line
Содержание KX-TA824
Страница 12: ...12 Installation Manual ...
Страница 78: ...3 2 Connection 78 Installation Manual ...
Страница 85: ...Installation Manual 85 Index ...