59
KX-PRW130W/KX-PRWA13W
11.6.1.2. Handset
First, operate the PC setting according to
The Setting Method of JIG (Handset)(
P.55).
Then download the appropriate data according to the following procedures.
Note:
(*3) W: country code, XXX_YYY: revision number
“XXX_YYY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in
The Setting
Method of JIG (Handset)
(P.55).
(*4) Refer to
Check Point (Handset)
(P.42)
Items
How to download/Required adjustment
BBIC (IC1)
Programming data is stored in memory.
1) System Clock adjustment.
EEPROM (IC5)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “55” to download
the data.
2) Default batch file: Execute the command “default.bat”.
3) Default batch file (remaining): Execute the command
“PRWA13US_DEF_RevXXX_YYY.bat”. (*3)
4) Country version batch file: Execute the command
“PRWA13US_W_RevXXX_YYY.bat”. (*3)
5) Clock adjustment: Refer to Check Point (H). (*4)
6) 1.8 V setting and battery low detection: Refer to Check Point
(A), (F) and (G). (*4)
X'tal (X1)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (C). (*4)