![Panasonic KX-PRW130W Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/panasonic/kx-prw130w/kx-prw130w_service-manual_263306023.webp)
23
KX-PRW130W/KX-PRWA13W
Frequently Used Items (Base Unit)
ex.)
Note:
(*1) Refer to
Registering a Handset to a Base Unit
in the Operating Instructions.
(*2) When you enter the address or New Data, please refer to the table below.
(*3)
Items
Address
Default Data
New Data
Remarks
C-ID(FSK) sensitivity
07 5D/07 5C
00/51
00/39
(3 dB up)
00/28
(6 dB up)
When the hex change from 00/51 to 00/39 or
00/28, gain increase by 3 dB or 6 dB.
C-ID(DTMF) sensitivity
07 63/07 62
08/00
0B/4C
(3 dB up)
0F/F6
(6 dB up)
When the hex change from 08/00 to 0B/FC or
0F/F6, gain increase by 3 dB or 6 dB.
SMS (FSK) receiving
sensitivity
07 5D/07 5C
00/51
00/39
(3 dB up)
00/28
(6 dB up)
When hex changes from “00/51” to “00/39” or
“00/28”, gain increases by 3 dB or 6 dB.
SMS (FSK) sending level
07 EE/07 EF
00/40
00/5A
(3 dB up)
00/7F
(6 dB up)
When hex changes from “00/40” to “00/5A” or
“00/7F”, gain increases by 3 dB or 6 dB.
Frequency
00 08/00 07
04/4A
-
-
Use these items in a
READ-ONLY
mode to
confirm the contents. Careless rewriting may
cause serious damage to the computer system.
ID
00 02~00 06
Given value
-
-
Bell length
03 FA
3C (6 sec) (*3)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing.
(Unit: 100 msec)
Desired Number (hex)
Input Keys
Desired Number (hex)
Input Keys
0
0
A
[R] + 0
1
1
B
[R] + 1
.
.
C
[R] + 2
.
.
D
[R] + 3
.
.
E
[R] + 4
9
9
F
[R] + 5
Bell length
3C (hex) = 60 (dec)
60
100 msec = 6000 msec (6 sec)