9.32 PBX Configuration—[1-4] Configuration—Clock
Priority
Shelf-Slot Number
Selects and prioritizes slot numbers for PRI cards that are used to forward a clock pulse from an external
source to the PBX.
Obtain the master clock time from the outside line that the telephone company provides.
To change Clock Priority, follow the steps below:
1.
Assign a Clock Priority to each slot.
2.
Set the status of the present clock source card to "
OUS
", then "
INS
".
Note
If multiple PBXs are used to establish a private network (TIE line service, QSIG network, etc.) without being
connected through the telephone company, assign only one PBX as the clock source on the network. That
PBX should have a card connected to a telephone company line selected as its clock source. All other
PBXs should have cards connected to the network selected as the clock source. This enables all PBXs on
the network to synchronize their timing.
Default
None
Value Range
None, Shelf and Slot number
Shelf and slot numbers are listed using the pattern "X-Y":
•
X: Shelf number (1–3 [2 and 3 correspond to Legacy Gateway 1 or 2])
•
Y: Slot number (1–11)
Maintenance Console Location
9.32 PBX Configuration—[1-4] Configuration—Clock Priority
476
PC Programming Manual
Document Version 2016-03
9.32 PBX Configuration—[1-4] Configuration—Clock Priority
Содержание KX-NS1000
Страница 32: ...32 PC Programming Manual Document Version 2016 03 1 2 3 PBX Configuration Types ...
Страница 60: ...60 PC Programming Manual Document Version 2016 03 2 3 Frequently Asked Questions FAQ ...
Страница 68: ...68 PC Programming Manual Document Version 2016 03 3 1 1 Home Screen Add Site Wizard ...
Страница 112: ...112 PC Programming Manual Document Version 2016 03 6 14 Tool URL Information ...
Страница 170: ...170 PC Programming Manual Document Version 2016 03 7 13 Utility Flash ROM ID Information ...
Страница 622: ...622 PC Programming Manual Document Version 2016 03 10 11 2 PBX Configuration 2 11 2 System Audio Gain Card ...
Страница 702: ...702 PC Programming Manual Document Version 2016 03 11 12 2 PBX Configuration 3 12 2 Group VM DTMF Group Group Settings ...
Страница 844: ...844 PC Programming Manual Document Version 2016 03 14 6 PBX Configuration 6 6 Feature Tenant ...
Страница 996: ...996 PC Programming Manual Document Version 2016 03 21 1 UM Configuration 2 Class of Service ...
Страница 1002: ...1002 PC Programming Manual Document Version 2016 03 22 2 UM Configuration 3 2 UM Extension Trunk Service Port Assignment ...
Страница 1082: ...1082 PC Programming Manual Document Version 2016 03 25 1 UM Configuration 6 H W Settings ...
Страница 1186: ...1186 PC Programming Manual Document Version 2016 03 27 12 Router Configuration QoS Settings 4 QoS Service ...
Страница 1232: ...1232 PC Programming Manual Document Version 2016 03 28 4 2 Network Service 4 2 Other NAS ...
Страница 1233: ...Section 29 Appendix Document Version 2016 03 PC Programming Manual 1233 ...
Страница 1241: ...Feature Programming References Document Version 2016 03 PC Programming Manual 1241 ...