Setting Features
Q
How do I change the dialling mode of an analogue trunk?
A
•
From the
3.30 [1-1] Slot—Port Property - LCO Port
screen, change the
Dialling
Mode
setting of the target port to "DTMF" or "Pulse", as required.
Q
How do I set disconnect detection (CPC Detection) for an analogue trunk?
A
•
From the
3.30 [1-1] Slot—Port Property - LCO Port
screen, modify the
CPC
Signal Detection Time—Outgoing, Incoming
setting of the target port.
The required value varies by carrier. Transmission and reception can be set
separately.
Q
What settings do I change to enable use of an extension ISDN telephone?
A
•
From the
3.33 [1-1] Slot—Port Property - BRI Port
screen, set the
Port Type
of
the port you want to use to "Extension".
Q
When using a TE with an extension ISDN, how do I enable power output?
A
•
From the
3.33 [1-1] Slot—Port Property - BRI Port
screen, set
ISDN TE Power
on the
ISDN Extension
tab to "Enable".
Q
How do I connect to another PBX using QSIG?
A
•
From the
3.33 [1-1] Slot—Port Property - BRI Port
or
3.35 [1-1] Slot—Port
Property - PRI Port
screen, set the
Port Type
of the port you want to use to either
"QSIG-Slave" or "QSIG-Master".
Q
How do I change the type of an extension port?
A
•
Set the port to OUS status. Then, change
DPT Type—Type
in the
3.24 [1-1] Slot
—Port Property - Extension Port
window.
Q
I have set the type of an extension port to "DSS Console", but I cannot apply this
setting. (Error E000402)
A
•
The number entered in
DPT Type—Location No.
on the
3.24 [1-1] Slot—Port
Property - Extension Port
screen is the same as that entered for another DSS
Console. Change this so that the numbers do not overlap.
Q
I have set the type of an extension port to "VM (DPT)", but I cannot apply this setting.
(Error E000403)
A
•
The
DPT Type—VM Unit No.
and
DPT Type—VM Port No.
settings entered on
the
3.24 [1-1] Slot—Port Property - Extension Port
screen are the same as those
entered for another VM (DPT). Change this so that the numbers do not overlap.
Q
I have set the type of an extension port to "PC Console", but I cannot apply this
setting. (Error E000402)
A
•
The number entered in
DPT Type—Location No.
on the
3.24 [1-1] Slot—Port
Property - Extension Port
screen is the same as that entered for another PC Console.
Change this so that the numbers do not overlap.
PC Programming Manual
103
2.7.1 Frequently Asked Questions (FAQ)
Содержание KX-NCP1000
Страница 11: ...Section 1 Overview This section provides an overview of programming the PBX PC Programming Manual 11 ...
Страница 14: ...Table 2 For CE model 14 PC Programming Manual 1 1 2 Entering Characters ...
Страница 15: ...Table 3 For RU model PC Programming Manual 15 1 1 2 Entering Characters ...
Страница 16: ...Table 4 For GR model 16 PC Programming Manual 1 1 2 Entering Characters ...
Страница 80: ...To view the error log From the Utility menu select Error Log 80 PC Programming Manual 2 6 8 Utility Error Log ...
Страница 106: ...106 PC Programming Manual 2 7 1 Frequently Asked Questions FAQ ...
Страница 107: ...Section 3 1 Configuration PC Programming Manual 107 ...
Страница 174: ...Feature Guide References None 174 PC Programming Manual 3 9 1 1 Slot Shelf Property Virtual IP Gateway ...
Страница 283: ...Feature Guide References None PC Programming Manual 283 3 32 1 1 Slot Card Property BRI type PRI type ...
Страница 457: ...Feature Guide References 1 25 1 Portable Station PS Connection PC Programming Manual 457 3 61 1 2 Portable Station ...
Страница 461: ...Section 4 2 System PC Programming Manual 461 ...
Страница 557: ...Feature Guide References None PC Programming Manual 557 4 17 2 8 3 Ring Tone Patterns Call from Others ...
Страница 594: ...594 PC Programming Manual 4 21 2 11 2 Audio Gain Card ...
Страница 595: ...Section 5 3 Group PC Programming Manual 595 ...
Страница 615: ...2 2 3 Tenant Service PC Programming Manual 615 5 7 3 2 User Group ...
Страница 617: ...Feature Guide References 1 4 1 3 Call Pickup 2 2 2 Group PC Programming Manual 617 5 8 3 3 Call Pickup Group ...
Страница 620: ...Feature Guide References 1 16 1 Paging 2 2 2 Group 620 PC Programming Manual 5 10 3 4 Paging Group ...
Страница 673: ...Section 6 4 Extension PC Programming Manual 673 ...
Страница 809: ...Programming Manual References None Feature Guide References None PC Programming Manual 809 6 17 4 3 DSS Console ...
Страница 811: ...Section 7 5 Optional Device PC Programming Manual 811 ...
Страница 827: ...Feature Guide References 1 17 8 Automatic Fax Transfer PC Programming Manual 827 7 4 5 3 2 Voice Message DISA Message ...
Страница 839: ...Section 8 6 Feature PC Programming Manual 839 ...
Страница 851: ...Feature Guide References 1 26 3 Call Charge Services PC Programming Manual 851 8 2 6 2 Hotel Charge ...
Страница 859: ...Section 9 7 TRS PC Programming Manual 859 ...
Страница 867: ...Section 10 8 ARS PC Programming Manual 867 ...
Страница 879: ...Section 11 9 Private Network PC Programming Manual 879 ...
Страница 892: ...892 PC Programming Manual 11 4 9 4 NDSS Key Table ...
Страница 893: ...Section 12 10 CO Incoming Call PC Programming Manual 893 ...
Страница 922: ...922 PC Programming Manual 12 7 10 5 Miscellaneous ...
Страница 923: ...Section 13 11 Maintenance PC Programming Manual 923 ...
Страница 961: ...Section 14 Appendix PC Programming Manual 961 ...
Страница 974: ...974 PC Programming Manual 14 1 8 KX TDE600 PGMPR Software File Version 4 1xxx ...
Страница 975: ...Feature Programming References PC Programming Manual 975 ...