background image

Installing the mounting bracket

Installing the mounting bracket on wooden walls

Line up the holes on the mounting bracket with the holes in the wall, then insert
and tighten each screw.

Note:

R

Use the supplied screws (

1

).

R

Place the bracket with the 

“UP”

 mark facing upwards.

1

1

Installing the mounting bracket on gypsum board, ALC (autoclaved
lightweight cellular concrete), or concrete blocks

Use the supplied anchors and screws to mount the mounting bracket to the wall.

Note:

R

Supplied anchors ø: 5 mm 

´

 25 mm.

R

Supplied screws ø: 4 mm 

´

 25 mm.

1

Mark the hole depth (

1

) on the drill bit at 35 mm and then drill the hole.

R

Use a 4.8 mm drill bit.

1

2

Remove debris.

13

Setup

Содержание KX-HNK101FX

Страница 1: ...NK101FX Thank you for purchasing a Panasonic product This document explains how to operate the access keypad properly For details about how to use the system refer to the User s Guide page 16 Please read this document before using the unit and save it for future reference ...

Страница 2: ...erformance 5 Other information 6 Setup Part names and functions 8 Touchpanel buttons 8 LED indicator 9 Setup overview 9 Registering the keypad 9 Confirming the usage area 10 Installation 11 Appendix Using the keypad 16 Features available when using the Home Network app 16 Accessing the User s Guide 16 Specifications 17 2 Table of Contents ...

Страница 3: ... subject to change without notice R The illustrations in these instructions may vary slightly from the actual product Trademarks R iPhone and iPad are trademarks of Apple Inc registered in the U S and other countries R Android is a trademark of Google Inc R Microsoft Windows and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and or ot...

Страница 4: ...adaptor power plug by pulling it from the power outlet then wiping with a dry cloth Accumulated dust may cause an insulation defect from moisture etc resulting in a fire R Unplug the product from power outlets if it emits smoke an abnormal smell or makes an unusual noise These conditions can cause fire or electric shock Confirm that smoke has stopped emitting and contact an authorised service cent...

Страница 5: ...sconnect device Ensure that the AC outlet is installed near the product and is easily accessible Important safety instructions When using your product basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Do not use this product near water for example near a bathtub washbowl kitchen sink or laundry tub in a wet ...

Страница 6: ...se your fingers to gently hold it in place taking care not to scratch it with your fingernails R Do not use any cleaning products that contain alcohol polish powder powder soap benzine thinner wax petroleum or boiling water Also do not spray the product with insecticide glass cleaner or hair spray This may cause a change in colour or quality of the product Disposal of Old Equipment Only for Europe...

Страница 7: ...on on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal 7 Important Information ...

Страница 8: ...r buttons are dimmed When you tap the touchpanel the arm mode buttons light for 10 seconds During this time you can tap an arm mode button to switch to the corresponding arm mode Button Status None displayed No power or buttons are turned off 1 lit Normal operation Arm At Home mode is selected lit Normal operation Arm Away mode is selected lit Normal operation Disarm mode is selected Current arm m...

Страница 9: ...d in the desired location Registering the keypad This procedure is not required for devices that were included as part of a bundle Before you can use the keypad it must be registered to the hub If you purchased devices separately i e not as part of a bundle you must register each device to the hub You can register each device by using the registration buttons or the Home Network app Note R Before ...

Страница 10: ...lls R When using each device on separate floors or in different buildings Note R The keypad s LED indicator blinks in red if it is out of range of the hub In this case confirm all connections including those of the hub Usage area cautions Using the keypad in the following areas may cause deformation malfunction or operational failure R In direct sunlight R Areas exposed to grease or steam such as ...

Страница 11: ...than 25 4 mm thick R The pull out strength of the installation area must be at least 29 4 N 3 kgf Determining the installation location Note R Make sure there is at least 20 cm of space to the left of the keypad when mounted so that the buttons on the side of the keypad can be accessed 1 Remove the mounting bracket R Place the keypad face down on a flat surface slide the bracket toward the bottom ...

Страница 12: ...s on the wall R Refer to the information below The dotted lines indicate where the edges of the keypad will be in relation to the mounting bracket C B D A C 16 mm 59 mm 19 mm Screw openings 60 mm apart 3 Drill pilot holes where you marked the screw openings in the previous step R The screw openings must be 60 mm apart 12 Setup ...

Страница 13: ...e bracket with the UP mark facing upwards 1 1 Installing the mounting bracket on gypsum board ALC autoclaved lightweight cellular concrete or concrete blocks Use the supplied anchors and screws to mount the mounting bracket to the wall Note R Supplied anchors ø 5 mm 25 mm R Supplied screws ø 4 mm 25 mm 1 Mark the hole depth 1 on the drill bit at 35 mm and then drill the hole R Use a 4 8 mm drill b...

Страница 14: ...t with the anchors then insert and tighten each screw R Use the supplied screws 2 R Place the bracket with the UP mark facing upwards 2 2 Installing the keypad to the mounting bracket Attach the keypad to the bracket R Insert the grooves on the keypad to the 4 tabs on the bracket and then push down the keypad 14 Setup ...

Страница 15: ...onnections AC adaptor connection R The AC adaptor must remain connected at all times It is normal for the adaptor to feel warm during use R The AC adaptor should be connected to a vertically oriented or floor mounted AC outlet Do not connect the AC adaptor to a ceiling mounted AC outlet as the weight of the adaptor may cause it to become disconnected Power failure R The keypad will not work during...

Страница 16: ...the current arm mode button blinks slowly Use the following procedure to stop the alert To cancel the trigger tap the touchpanel enter the disarm PIN default 0000 and then tap MOKN Talking notification feature This feature allows you to get information about a triggered sensor When a sensor is triggered the keypad can announce the location of the sensor detected the sensor name and the type of det...

Страница 17: ...web page listed below www panasonic net pcc support tel homenetwork manual Specifications R Standards DECT Digital Enhanced Cordless Telecommunications R Frequency range 1 88 GHz 1 90 GHz R RF transmission power Approx 10 mW average power per channel 250 mW max R Power source 220 240 V AC 50 60 Hz R Power consumption Standby Approx 0 6 W Maximum Approx 2 0 W R Operating conditions 0 C 40 C R Dimen...

Страница 18: ...18 Notes ...

Страница 19: ...19 Notes ...

Страница 20: ... a record of the following information to assist with any repair under warranty Serial No Date of purchase found on the rear of the unit Name and address of dealer Attach your purchase receipt here Panasonic Corporation 2016 PNQP1213YA CC0216WK1126 ...

Отзывы: