Digiplex & DigiplexNE
-
1
-
Module
s
Programming Guide
48-Zone LED Keypad Module
This model does not support installer programming capabilities, therefore you cannot program other modules or the panel on the
combus using this unit.
*000=disabled; 001=A1; 002=A2; 003=A3; 004=A4.
Do not assign the same display number to more than one section. A maximum of 4 partitions can be displayed on the keypad.
U
=
Default Settings
Section
Data
Description
Default
[001]
__/__/__ (000 to 004)*
Partition 1 Display
001 = (LED A1)
[002]
__/__/__ (000 to 004)*
Partition 2 Display
002 = (LED A2)
[003]
__/__/__ (000 to 004)*
Partition 3 Display
003 = (LED A3)
[004]
__/__/__ (000 to 004)*
Partition 4 Display
004 = (LED A4)
[005]
__/__/__ (000 to 004)*
Partition 5 Display
000
[006]
__/__/__ (000 to 004)*
Partition 6 Display
000
[007]
__/__/__ (000 to 004)*
Partition 7 Display
000
[008]
__/__/__ (000 to 004)*
Partition 8 Display
000
SECTION [009] : Keypad Options
SECTION [010] : Beep on Trouble
Option
OFF
ON
Option
OFF
ON
[1]
Confidential Mode
U
Disabled
N
Enabled
[1]
Beep on System Trouble/Clock Loss
U
Disabled
N
Enabled
[2]
Exit Confidential Mode
U
Press key
N
Enter code
[2]
Beep on Communicator Trouble
U
Disabled
N
Enabled
[3]
Muting
U
Disabled
N
Enabled
[3]
Beep on Module/Combus Trouble
U
Disabled
N
Enabled
[4]
Beep on Exit Delay
N
Disabled
U
Enabled
[4]
Beep on Zone Trouble
U
Disabled
N
Enabled
[5]
Chime on Zone Closure
U
Disabled
N
Enabled
[5] to [8]
Future Use
N
N/A
N
N/A
[6] to [8]
Future Use
N
N/A
N
N/A
SECTION [011] : PGM & Keypad Tamper Options
Option
OFF
ON
[1]
PGM State
U
N.O.
N
N.C.
[2]
PGM Deactivation Mode
U
Deactiva-
tion Event
N
PGM Timer
[3]
PGM Base Time
U
1 second
N
1 minute
[4]
Future Use
N
N/A
N
N/A
[5]
Keypad Tamper
U
Disabled
N
Enabled
[6] to [8]
Future Use
N
N/A
N
N/A
DGP2-648