12. CHECK PROCEDURE (BASE UNIT)
12.1. Preparation
12.1.1. Equipment Required
- DECT tester: Rohde & Schwarz, CMD 60 is recommended.
- Frequency counter: it must be precise to be able to measure 1Hz
(precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
- DC power: it must be able to output at least 1A current under 9V.
- Digital multi-meter (DMM): it must be able to measure voltage and
current.
- Oscilloscope
12.1.2. JIGs and PC
- EEPROM serial JIGs
1. I2C PCB: PQZZTCD705BX
2. RS232C cable: PQZZ1CD705BX
3. Clip cable: PQZZ2CD705BX
4. DC cable: PQZZ3CD705BX
- PC which runs in DOS mode
- Batch file for setting: PQZZTCD410AX
12.2. PC Setting
12.2.1. Connections
12.2.2. PC Setting
1. Open a window of MS-DOS mode from the start-up menu.
2. Change a directory to the one with “RTX_COM” contained.
3. Type “SET RTX_COM=1” from the keyboard (when COM port 1 is used
for the connection).
34
www.freeservicemanuals.info
11/8/2014
Digitized in Heiloo, Holland
Содержание KX-A141AXM
Страница 23: ... To exit the operation press any time 23 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 51: ...18 FREQUENCY TABLE MHz 51 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 58: ...25 CPU DATA BASE UNIT 25 1 IC2 BBIC 58 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 74: ...74 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 76: ...76 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 82: ...82 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 104: ...PbF R1 R2 TP4 TP1 TP2 TP3 Digital Volt Meter 12Ω 2W A www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...