Items
Adjustment
Point
Procedure
Check
Replac
Parts
(K
)
Frequency
Offset
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Confirm that the frequency offset is < ± 50kHz.
IC1, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
(L)
Sensitivity
Receiver
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Set DECT tester power to -88dBm.
6. Confirm that the BER is < 1000ppm.
IC1, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
(M
)
Timing
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Confirm that the Timing accuracy is < ± 10ppm.
IC1, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
(N
)*
RSSI Level
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Set DECT tester power to -88dBm.
6. Execute the command "readrssi"
7. Confirm that the returned value is 0x34 ± A (hex).
IC1, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
48
www.freeservicemanuals.info
11/8/2014
Digitized in Heiloo, Holland
Содержание KX-A141AXM
Страница 23: ... To exit the operation press any time 23 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 51: ...18 FREQUENCY TABLE MHz 51 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 58: ...25 CPU DATA BASE UNIT 25 1 IC2 BBIC 58 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 74: ...74 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 76: ...76 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 82: ...82 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 104: ...PbF R1 R2 TP4 TP1 TP2 TP3 Digital Volt Meter 12Ω 2W A www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...