A&W Food Services of Canada Inc. 

English Touch Screen Cable Kit Guide V970 2.2.docx  QSR Solutions 

Page 3 

 

ELECTRICAL REQUIREMENTS 

 
The most probable cause of a system malfunction is due to improper electrical wiring. 

The following electrical requirements MUST be met before the installation to prevent 

problems. 

*

 

The complete system, including touch screen terminals, video monitors, printers, 

kitchen video controller and the back office computer MUST be on a single 

DEDICATED circuit originating at the main breaker. 

*

 

The dedicated circuit must be 120V, 60 Hz, 15 amps, 3 wire (including ground). 

*

 

The ground wire must connect to a primary isolated ground, NOT to a conduit or 

gas pipe. 
 

AC WIRING (TO BE COMPLETED BE THE GENERAL CONTRACTOR) 

1)

 

All components in the POS system are to be connected to a dedicated AC line. 

2)

 

There should only be one AC line originating at the main panel for the store.  

3)

 

15 AMP breaker is sufficient. 

4)

 

The AC line must have an isolated ground and utilize HUBBEL IG5262 – DUPLEX 
ORANGE
 receptacles. 

5)

 

AC wire must be run in conduit that contains 3 wires HOT – NEUTRAL – GROUND

6)

 

No other wiring for other conduits can be run in this conduit. 

7)

 

You may use BX instead of conduit. 

8)

 

Voltage provided in 117.5 VAC (+/- 15%). 

9)

 

Ground wires must be INSULATED

10)

 

An ISOLATED ground wire is required and should be run from the receptacles to 

the main building ground. 

11)

 

You may also run the ground to a water pipe AS WELL AS the main ground. 

 

An orange duplex, 3 wire, grounded receptacle must be installed at the following 
locations: 

 

Every touch screen terminal site including the drive-thru and kiosk 

(maximum 3 feet from the device) 

 

The main network rack, patch panel/switch. This is located above the 

manager’s desk cupboard between the top of the cupboard and ceiling 
tile or on the top shelf inside the cupboard if there is no space on top. 

 

The front line expeditor monitor (maximum 2 ½’ from the monitor) 

 

The grill monitor (maximum 2 ½’ from the monitor) 

 

The fryer monitor (maximum 2 ½’ from the monitor) 

 

The prep monitor if applicable (maximum 2 ½’ from the monitor)  

 

The drive-thru monitor if applicable (maximum 2 ½’ from the monitor) 

 

The back office computer. If the computer is to be located inside the 
cupboard of the manager’s desk. 

NOT ALLOWED 

x

 

Non Hubbel (NON-IG) receptacles 

x

 

No alternative equipment (calculators, coffee warmers, compressors, etc. 

to be used on this circuit 

x

 

More than one single circuit for the entire system 

x

 

Never terminate the ground in the panel with other store grounds 

x

 

Isolators or conversion plugs are not allowed 

 

 

Содержание JS-970 Series

Страница 1: ...e in the process of remodeling give this manual to your construction supervisor electrical engineer contractor and electrician so that they may incorporate the system s requirements into their construction plans It is your responsibility to provide the pre installation preparations before the Panasonic Representative arrives The system may not be installed if all the preparations are not completed...

Страница 2: ...mp bar to the Grill Monitor as per enclosed specifications Install the kitchen video monitor system KVS MONITOR MOUNT BRACKETS Installation instructions are included with each mounting bracket Please refer to the building plans for mounting locations Cut the 1 HOLES in the counters for the cables to pass through Holes should be center of where the cash register sits approximately 6 in from the fro...

Страница 3: ...y use BX instead of conduit 8 Voltage provided in 117 5 VAC 15 9 Ground wires must be INSULATED 10 An ISOLATED ground wire is required and should be run from the receptacles to the main building ground 11 You may also run the ground to a water pipe AS WELL AS the main ground An orange duplex 3 wire grounded receptacle must be installed at the following locations Every touch screen terminal site in...

Страница 4: ...cable is provided for all Ethernet communication runs 2 The CAT5 cabling must be home runs from the patch panel to all devices per the enclosed specifications 3 One CAT5 run must be installed from the patch panel to the burger chute order printer 4 One CAT5 run must be installed from the drive thru order taker terminal to the drive thru speaker post for the OCB display 5 The CAT5 runs use a standa...

Страница 5: ...lding plans for exact system configuration and equipment placement CAT5e Communications Cable BLUE WIRE Leave 6 of cable at each location for termination QSR will terminate the cables Kiosk T5 Patch Panel Counter T1 Counter T2 Drive Thru Order Taker T4 Drive Thru Cashier T3 Burger Chute Printer The Network rack patch panel is located above the Manager s desk on the top shelf or on the top of the c...

Страница 6: ... Please refer to your building plans for exact system configuration and equipment placement IMPORTANT NOTE The CAT5 BLACK cable is for the video monitors E Pic Video Controller Bump Bar CAT5 Black Video Cable CAT5 White Bump Bar Cable 30 Audio Cable The Video Splitter and E Pic Video Controller are usually located above the Manager s desk on the top shelf or on the top of the cabinet Diagram 1b Ki...

Страница 7: ...5W 10 125H 1 125D Dimensions are in inches Speaker Post Dimensions 19 0W 52 0H 11 0D Dimensions are in inches Electrical Requirements 24VAC power adaptor at the speaker post Standard CAT5 communications cable It is the contractor s responsibility to have the communications cable run by the on site electrician new stores CAT5 Cable Supplied with speaker post ...

Страница 8: ...elphi Drive Thru OCB 192 168 11 71 Port 7 N A Port 7 TM 88IV IP printer 192 168 11 72 Port 8 N A Port 8 Time Shark 192 168 11 73 Port 9 N A Port 9 E pic Video Controller 1 192 168 11 90 Port 10 N A N A Digital Menu Board 1 Dynamic Port 11 N A Port 11 Digital Menu Board 2 Dynamic Port 12 N A Port 12 Digital Menu Board 3 Dynamic Port 13 N A Port 13 Digital Menu Board 4 Dynamic Port 14 N A Port 14 Di...

Отзывы: