10
Technical data common to all models
7.3 Electromagnetic compatibility (EMC)
Radiated disturbance test
Class A
CISPR 22
CISPR 16-2-3
Electrostatic discharge immunity
test
8kV (air electrostatic discharge)
4kV (contact electrostatic discharge)
EN 61000-4-2
Radiated, radio frequency,
electromagnetic field immunity
test
80MHz–1GHz, 10V/m
1.4–2GHz, 3V/m
2–2.7GHz, 1V/m
EN 61000-4-3
Burst immunity test
±2KV DC power port
±1KV signal line
EN 61000-4-4
Surge immunity test
±0.5KV DC power port (line to earth)
±0.5KV DC power port (line to line)
±1KV signal line (line to earth)
EN 61000-4-5
Immunity to conducted
disturbances inducted by radio
frequency field
0.15–80MHz, 10V
EN 61000-4-6
Power frequency magnetic field
immunity test
Enclosure, 50/60Hz, 30A/m
EN 61000-4-8
7.4 Durability information
Backlight service life (LED type)
40000 hours or more
(Time of continuous operation until the brightness of the back-
light reaches 50% of the rated value when the surrounding air
temperature is 25°C, see note*)
* Extended use in environments where the surrounding air temperature is 40°C or higher may degrade backlight
quality, reliability or durability.
7.5 Viewing angles
The viewing angles for the horizontal (L, R) and vertical (U, D) axes are specified in reference to the
vertical axis of the display. The viewing angles always refer to the standard mounting orientation.
For the viewing angle values (U, D ,R ,L), refer to the technical data of the respective touch terminal
model.
U: From top
L: From left
D: From bottom
R: From right