Functions
HL-G1 User's Manual
70
1.
2.
3.
Procedure
1.
2s
2.
5x
3.
4.
5.
6.
or
to change the setting
7.
to confirm
4.4.6.3 Alarm Delay
Sets the number of measurement attempts to be made before an alarm
is output.
When an alarm occurs, for example because measurement was not possible due to lack of
light, it will not be output immediately. Instead, the sensor holds and displays the last normal
measurement value until the number of times set here has been reached. When the number
of times set here has been exceeded, the alarm output (OUT3) will be turned ON. The analog
and the digital output will be turned ON according to the setting for analog output at alarm and
the setting for digital output at alarm, respectively.
NOTE
This function is useful if you do not require an alarm output as soon as the
surface of measured objects changes.
Setting range
Function
Initial value
0 to 65534
0 (OFF) to 65534 times
65535
Holds the last measurement value before the
alarm occurred.