Functions
HL-G1 User's Manual
58
2.
3.
4.
5.
3x
6.
to display the current scaling factor
The leftmost digit is selected. Press
and
together to select the next digit.
7.
to change the selected digit
8.
to confirm
4.4.3.4 Offset
Sets an offset value to be added to/subtracted from the measurement
value.
Setting range
Function
Default setting
-95000 to +95000
Set an offset in a range from 95000 to +95000.
(The position of the decimal point varies with each
model.)
NOTE
To use the size of a master workpiece as an offset, measure it with the
sensor and then input the set-to-zero signal.
Set "Offset" and turn "Zero Set" ON to make the setting value an offset va-
lue.
The display limit of the measurement value is ± 95000. Make sure that the
setting value does not exceed the display limit.