Analysis Mode
This function is used to set the analysis mode.
The following table shows the function of each analysis mode.
Setting
Function
Panel display
NORMAL
The measurement
value is output in real
time.
PEAK
Holds and outputs the
maximum
measurement value.
VALLEY
Holds and outputs the
minimum
measurement value.
PEAK to PEAK
(
P-P
)
0
Holds and outputs the
difference between the
maximum and
minimum values.
*
indicates the default value.
Peak to Peak can be used for vibration or eccentricity measurement.
● Setting Procedure
1
Display the "Data Processing Setting"
screen while the system is in setting mode.
2
Press the [ENTER] key.
The "Average
Time" screen will be displayed.
3
Press the [DOWN] key once. The
"Analysis Mode" screen will be displayed.
4
Press the [ENTER] key. The present
analysis mode will be displayed.