Class
Function
Details
Initial value
Memory
change*
Ref.
page
Zero-set
Sets the measurement value to zero.
-
Reset
Resets the measurement value.
Default: OFF
-
Buf
fer
ing S
et
tin
gs
Buffering Mode
Sets the buffering mode.
Default: Continuous mode
Buffering Rate
Loads measurement data for a long duration by
decimating the measurement data during data
accumulation.
Default: 1/10
Accumulated Amount
Sets the amount of accumulated data.
Default: 3000 data items
Trigger Point
Sets the trigger generation position in the accumulated
data.
Default: 300
Trigger Delay
Delays the timing of accumulation after the trigger
generation.
Default: 0
Trigger Conditions
Sets the conditions of trigger generation.
Default: At timing input ON
Buffering Operation
Starts buffering with buffering-related parameters set
in advance.
Status Readout
Checks the operation status of accumulation.
-
Last Data Point
Reads out the accumulation status from the amount of
measurement data.
-
Binary Readout of
Buffering Data
Reads out the accumulated data.
-
* Memory change
: Up to four types of settings can be saved by performing memory
change.
: Settings cannot be changed by performing memory change.
: Settings are saved as common settings for all memories. Settings cannot
be executed on a memory-to-memory basis.
•
COM settings and buffering settings are functions dedicated to the high-function
type. These settings are not used for the standard type.
•
Buffering settings cannot be made through the control panel. Make settings with
serial communications commands.
•
Each set value is saved in either one of the following ways depending on the
operating method selected.
<Control panel of sensor head>
Press the [ENTER] key to save after a set value change is made.
<Serial communications command (High-function type only)>
Execute the “Save” command after making a setting change.
The execution of the “Save” command is required after making a setting change
in the case of using the Setting and Monitoring Software HL-G1SMI for the
dedicated console (sold separately).
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
Содержание HL-G1*A-RA-C5 Series
Страница 18: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com ...
Страница 98: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com ...
Страница 130: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com ...
Страница 157: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com ...