Output Settings
Item
Command
Data
Description
Format
O
ut
put
S
et
ti
ngs
Judgment Output
Selection
ROD WOD
+00000
Logic
FORMAT
1
+00001
Independent
+00002
2-state
+00003
3-state
Displacement
Judgment
Threshold
a
RHA WHA
-9500000 to
+9500000
-950.0000 to
+950.0000 [mm]
FORMAT
2
Threshold
b
RHB WHB
-9500000 to
+9500000
-950.0000 to
+950.0000 [mm]
Hysteresis
RHH WHH
+0000000 to
+9500000
+000.0000 to
+950.0000[mm]
Judgment Output
OFF-delay
ROF WOF
+00000
OFF
FORMAT
1
+00001
2[ms]
+00002
4[ms]
+00003
10[ms]
+00004
20[ms]
+00005
40[ms]
+00006
100[ms]
+00007
Hold
Measurement Value
Display on Panel
RDS WDS
+00000
FULL
+00001
SET 1
+00002
SET 2
*1. The data section consists of 5 digits (zero suppress is omitted) indicated in
decimal.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com