ELECTRICAL CONNECTIONS 

Be sure your appliance is properly installed and grounded 
by a qualified technician. Ask your dealer to recommend a 
qualified technician or an authorized repair service. 

This appliance is manufactured with a green GROUND wire 

connected to the oven chassis. After making sure that the 

power has been turned off, connect the flexible conduit from 

the oven to the junction box using a U.L. listed conduit 

connector. Figures A and B and the instructions provided 

below present the most common way of connecting the ovens. 

Your local codes and ordinances, of course, take precedence 

over these instructions. Complete electrical connections 

according to local codes and ordinances  

“WARNING” Risk of Electric Shock, frame grounded to 
neutral of appliance through a link

Grounding through the neutral conductor is prohibited for new 

branch-circuit installations (1996 NEC); mobile homes; and 

recreational vehicles, or in an area where local codes prohibit 

grounding through the neutral conductor. For installations 

where grounding through the neutral conductor is prohibited: 

Disconnect the ground from the neutral at free end of 

conduit; 
Use grounding terminal or lead to ground unit; and 
Connect neutral terminal or lead to branch circuit neutral in 

usual manner. 

 

 

Figure A

                                               Figure B

 

FINAL CHECKLIST 

To prevent improper connections leading to damage of 

electrical components and so voiding the warranty, the 

following steps must be performed: 

1.  Check the electrical requirements and make sure you have 

the correct electrical supply and that the oven is properly 

grounded. 

2.  Turn on the power supply to the oven.   

3.  Check power at the junction box wires using a voltmeter 

having a range of 0-250V.  

If you have installed the oven for use on 240V supply, 

you should find that the voltage reading between the black 

and red wires (Line to Line) should be 220V to 240V.  

If you have modified the oven(s) for use on 208V, the 

voltage reading between the black and red wires should be 

190 to 208V. 

4.  Set the clock by following these steps:  

Clock is now set. 

5.  Test the bake mode by following this step:  

Move cooking mode knob to “BAKE” position. 
Cooling fan, oven lights, preheat led will turn on. 
A beep is sounded when the oven reaches the preset  

350 °F (175 °C) and the preheat light turn off. 
Move the knob back to “OFF” position to stop cooking. 

6.  To check the other oven functions refer to the “Using the 

Oven Controls” section of the USER MANUAL. 

7.  If the oven is working properly, turn off the power supply to 

the oven. 

8.  Place the cover on the junction box and make sure the 

cover is securely fastened and turn on the power to the 

oven. 

Leave these INSTALLATION instructions as well as the 

 

 

Operating Instructions with the owner.

3-WIRE BRANCH CIRCUIT  (for US only)

4-WIRE BRANCH CIRCUIT (for US and CANADA)

 Press

   

[TIME] key twice until the display shows “SET TIME”.

  Immediately press + [INC] or - [DEC] keys to set hours.

 Press

   

[TIME] key again to change minutes.

  Immediately press + [INC] or - [DEC] keys to set minutes, hold to 

change by ten (10) minutes step.

 Press

   

[TIME] key or wait for a few seconds.

Refer to Figure A, where local codes allow the connection of
GROUND wire from the oven to the branch circuit NEUTRAL
wire (gray or white colored wire):

 

If local codes permit, connect the green GROUND wire 
from the oven and the white wire from the oven to the 
branch circuit NEUTRAL wire (gray or white colored wire).

 

Connect the red and black leads from the oven to the 
corresponding HOT Wires in the junction box.

 

Connect the local codes and power supply codes using a 
terminal.

 

The terminal uses a thing adapting to the wire of the cord.

Refer to Figure B:

 

Disconnect ground from neutral at free end of conduit.

 

Connect the green GROUND wire from the oven to the 
GROUND wire in the junction box (bare or green colored wire).

 

Connect the red and black leads from the oven to the 
corresponding HOT Wires in the junction box.

 

Connect the white wire from the oven to the NEUTRAL (gray or 
white) wire in the junction box.

 

Connect the local codes and power supply codes using a 
terminal.

 

The terminal uses a thing adapting to the wire of the cord.

From power 

supply

From the oven

Terminal Block

Square-wire spring

Important: Use twist-on connector

with square-wire spring

Or

Содержание HL-BD82S

Страница 1: ...En particular leer el apartado ADVERTENCIA Y PRECAUCIONES antes de realizar cualquier operaci n de montaje Proper installation is the responsibility of the installer Any malfunction or accident resul...

Страница 2: ...quency The oven is manufactured to be connected to a three wire or four wire single phase 120V 240V 60 Hz AC electrical supply on a separate circuit fused on both sides of the line If a 120V 208V circ...

Страница 3: ...ided Failure to do so could result in oven moving or tipping during use and causing damage to the oven or cabinets or personal injury Know how to disconnect the power to the oven at the circuit breake...

Страница 4: ...ight corner supply junction box Secure oven to cabinet using the screws provided Screws should be inserted through the mounting holes in the positions indicated in the frame open door to see frame and...

Страница 5: ...INSTALLATION Ltr DIMENSION F Cutout Width G Cutout Height H Visible part of the mounting strips SINGLE 30 30 1 16 76 4 cm 28 1 32 71 2 cm 3 4 1 9 cm Mounting strip Finished sides the cabinet 61 cm I...

Страница 6: ...unding DO NOT ground to a gas pipe DO NOT have a fuse in the NEUTRAL or GROUNDING circuit A fuse in the NEUTRAL or GROUNDING circuit could result in an electrical shock Check with a qualified electric...

Страница 7: ...by following these steps Clock is now set 5 Test the bake mode by following this step Move cooking mode knob to BAKE position Cooling fan oven lights preheat led will turn on A beep is sounded when t...

Страница 8: ...09PN5980 10 12 Printed in Italy Imprim en Italie Estampado en Italia Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 www panasonic ca Panasonic Corporation 2012...

Отзывы: