5
Figure 1. Module Dimension
VBHNxxxSA17E, VBHNxxxKA03E
Dimension in mm
Note) A module is installed using 4 points, symmetrical mounting within setting range (Black arrows).
Setting range parameters are shown in “Mount Locations and Load Resistance” table.
Note)
※
Production up to October 2019 is 150mm. Production after November 2019 is 215mm.
So, Please check the production date properly.
Note) Load Resistance shown above is UL Test-Load.
Design load is a value obtained by multiplying the above value by two thirds.
Table 1-2. Mount location and Load Resistance
Mounting location range
(mm)
L1
0
230
230
-
L2
450
380
345
-
S1
-
-
-
0
S2
-
-
-
250
Load Resistance (Positive Load)
50 psf
112 psf
112 psf
50 psf
Load Resistance (Negative Load)
50 psf
91 psf
112 psf
50 psf
(
2400 Pa)
(
5400 Pa)
(
5400 Pa)
(2400 Pa)
(
2400 Pa)
(
4400 Pa)
(
5400 Pa)
(
2400 Pa)
Side
Front
Backside
Section B-B
Section A-A
M
a
x 2
70mm