15
CONNECT TO A JUNCTION BOX
OR AN ENPHASE Q AGGREGA-
TOR
Connect the Enphase Q Cable into
the Enphase Q Aggregator (See
Figure 14).The Enphase Q Cable
uses the following wiring color
code. A ground lug is provided on
the Q Aggregator for convenient
PV module/rack/balance of system
(BOS) grounding.
Refer to the wiring diagrams on
Figure 15 for more information.
Wire colors are listed in the fol-
lowing table.
ENERGIZE THE SYSTEM
Turn ON the AC disconnect or circuit
breaker for the branch circuit.
Turn ON the main utility-grid AC
circuit breaker. Your system starts
producing power after a five-minute
wait time.
Check the LED on the connector
side of the microinverter:
LED color
Indicates
Solid Red
There is an active “DC Resistance Low, Power Off Condition.” To
reset, see “DC Resistance Low – Power Off Condition” on page 22
of IQ7X INSTALLATION AND OPERATION MANUAL.
Flashing
green
Normal operation. AC grid function is normal there is communica-
tion with the IQ Envoy.
Flashing or-
ange
The AC grid is normal but there is no communication with the IQ
Envoy.
Flashing Red
The AC grid is either not present or not within pecification.
Figure 14. Connect to a junction box
or an Enphase Q Aggregator
Содержание HIT VBHN340SA17E
Страница 10: ...10 Figure 8 Installation Map 1 ...
Страница 11: ...11 Figure 9 Installation Map 2 ...
Страница 23: ...23 Figure 17 Expanding the nails of the four corners ...