MODULE INSTALLATION
Install modules where they are not
shaded by obstacles like buildings or
trees. Especially pay attention to
avoid partially shading the modules
by objects during the daytime.
Water stains might be caused when
rain water remains on the glass
surface for a long time. To avoid
water stains, Panasonic recom-
mends to install modules at a slope
steeper than the water gradient.
Modules should be firmly fixed in
place in a manner suitable to with-
stand all expected loads, including
wind and snow loads.
Metals used in locations that are
exposed to moisture shall not be
employed alone or in combinations
that could result in deterioration or
corrosion.
The clamps should be made of alu-
minum alloy or other material that
will reasonably protect against a risk
of electrolytic corrosion.
Clearance between the roof surface
and module frame is required to
allow cooling air to circulate around
the back of the module. This also
allows any condensation or mois-
ture to dissipate. The required
clearance between the roof surface
and the module is more than 4 inch.
The modules should be mounted
basically at the four (4) quarter
points by the means shown in Figure
1, and based on installation meth-
ods shown in Figure 5.
Figure 5 shows using a bolt and nut
for mounting.
Do not contact a tip of a mounting
bolt to back sheet of the module
when fixing the module to the
mounting structure rail.
Recommendation of bolt torque: 10
ft-lbs.
Figure 5 shows that a module
should be attached on a mount or
support structure rail by corrosive-
resistant metal clamps.
Appropriate material should be
used for mounting hardware (the
module frame, mounting structure,
and hardware) to prevent itself
from corrosion.
Panasonic does not provide a war-
ranty for clamps. The module war-
ranty Panasonic provides shall be
voided if clamps selected by the
customer are of an improper materi-
al or size.
Please contact your Panasonic Au-
thorized Representative with ques-
tions regarding mounting profiles
for modules if needed.
The module was tested using Iron-
Ridge clamps with the specifications
see Figure 5 and below;
IronRidge clamps:
Provider: IronRidge Inc.
Product Line: RoofMount
Clamps type: Top Mounting Clamps
(Universal Fastening Objects(UFOs)
and Stopper Sleeves)
IronRidge Part No. UFO-CL-001,
UFO-CL-001B, UFO-STP-40MM, UFO-
STP-40MM-B
Width: Universal Fastening Objects;
1.12”(28.4 mm), Stopper Sleeves;
1.09”(27.7 mm)
Thickness: Universal Fastening Ob-
jects 0.29”(7.4mm),
Torque: 9.04 N.m (80 in-lbs).
Material: Universal Fastening Ob-
jects; 300 Stainless steel, Stopper
Sleeves; 6000 Aluminum alloys
Note: Please refer to IronRidge
manual, for installation method.
Module
Stopper Sleeves
1.12”
0.37”
7/16” Head
Universal Fastening Objects
End clamp
7/16” Head
0.37”
<Ironridge clamps>
Mid clamp
Figure 5. Module Installation
Solar Module
Module
Mounting Structure Rail
5/6” or M8 Nut
(Stainless steel)
Flat washer
(Stainless steel)
Flat washer
(Stainless steel)
Spring washer
(Stainless steel)
5/6” or M8 Nut
(Stainless steel)