Figure 2.  Junction Box  

Positive ( + ) 

Negative ( - ) 

STANDARDS 

VBHNxxxSA and VBHNxxxKA series com-

ply with the requirements of UL1703. 

FIRE CLASS OF PRODUCT 

 

The fire rating of this module is valid 

only when mounted in the manner 

specified in the mechanical mount-

ing instructions.

 

 

The models in this instructions are 

suitable to maintain the System Fire 

Class Rating A when used with a 

Listed mounting system and a roof 

covering that have been rated as a 

Class A System when installed on a 

steep slope roof and/or a low slope 

roof with "Type 2" modules.

  

JUNCTION BOX AND TERMINALS 

 

Modules equipped with one junc-

tion box contain terminals for both 

positive and negative polarity, and 

bypass diodes. 

 

Each terminal is dedicated to one 

polarity (with the polarity symbols 

engraved onto the body of the junc-

tion box) (see Figure 2). 

 

Each terminal is provided with facto-

ry installed lead cables and a latch-

ing connector for series and string 

connections. Always use these con-

nectors and do not detach them 

from cables.  

 

The PV module comes pre-wired. 

Each module has two #12 AWG type 

PV-wire stranded sunlight resistant 

output cables each terminated with 

connectors. The positive (+) terminal 

has a male connector while the neg-

ative (-) terminal has a female con-

nector. The module wiring is solely 

for series connections only, i.e. male 

(+) to female (-) interconnections. 

When making field wiring connec-

tions to the preattached connectors 

use only approved connectors from 

Table.2. 

 

Latching connectors are type IV and 

made by STAUBLI ELECTRICAL CON-

NECTORS AG. Supplied connectors 

listed by UL. 

 

In order to comply with NEC 2008, a 

locking sleeve needs to be used with 

all connectors that are exposed. 

 

The locking sleeve (PV-SSH4) is 

made by STAUBLI and can only be 

released with a special tool also 

made by STAUBLI (PV-MS). Locking 

sleeves are not supplied with mod-

ules and must be purchased sepa-

rately. 

BYPASS DIODE 

 

When the modules in series strings 

are shaded partially, it may cause 

reverse voltage across cells or mod-

ules, because the current from other 

cells in the same series is forced to 

flow through the shaded area. This 

may cause undesirable heating to 

occur. 

 

The use of a diode to bypass the 

shaded area can minimize both 

heating and array current reduction. 

 

All modules are equipped with fac-

tory installed bypass diodes. The 

factory installed diodes provide 

proper circuit protection for the 

systems within the specified system 

voltage, so that you do not need 

any other additional bypass diodes. 

 

Specifications of bypass diode for 

VBHNxxxSA and VBHNxxxKA mod-

ules are as follows; Type: Number of 

bypass diode: 4 diodes, Number of 

series cells per bypass diode: 24 

cells / diode  (See Figure 3).  

 

 

24 cells / 

24 cells / 

24 cells / 

24 cells / 

Figure 3. Number of series cells per bypass diode 

Figure 2. Connectors 

Option:  

Safety lock 

Connector 

Cable 

Negative ( - ) 

Positive ( + ) 

Manufacturer 

 

STAUBLI ELECTRICAL CONNECTORS AG

 

Contact Information

 

http://ec.staubli.com

 

Model #

 

PV-KST4, PV-KBT4 followed by /2.5 or /6, followed by "I" or "II", followed by 
-UR. or - may be followed by additional suffixes, may be followed by suffix 
numbers and letters. 

  

PV-PLS-S, PV-PLS-B, may be followed by suffix numbers and letters, may be 
followed by suffix numbers and letters. 

  

Male PV connectors, 

PV-KST4-EVO2/2.5, 6 or 10, followed by I, II, III or IV, followed by -UR. 

Female PV connectors, 

PV-KBT4-EVO2/2.5, 6 or 10, followed by I, II, III or IV, followed by –UR 

 

Table.2 Approved connectors list  

Содержание HIT VBHN330SA17

Страница 1: ...service names listed in this manual are trademarks or registered trademarks of respective companies General Installation Manual VBHNxxxSA series VBHNxxxKA series Photovoltaic Module HIT Thank you for choosing Panasonic photovoltaic module HIT Please read this manual completely before you install or use of HIT With proper operation and maintenance HIT will pro vide you with clean renewable solar el...

Страница 2: ...alla tion and handling of the modules The shock hazard increases as mod ules are connected in parallel pro ducing higher current and as mod ules are connected in series produc ing higher voltages The shock hazard increases as mod ules with nominal open circuit volt age Voc in excess of 50 V and or modules rated for maximum system voltage in excess of 50 V Wear suitable clothing gloves and guards t...

Страница 3: ...AL LOADING The modules should be mounted at the four 4 quarter points by the means shown in Figure 1 This method offers a maximum load shown as Mount Location and Load Resistance in Figure 1 in a static state on the module surface Note This mechanical loading value was tested using the mounting de vice specified in section MODULE INSTALLATION As UL Certified Load Ratings this module meets design l...

Страница 4: ... 69 6 70 9 70 5 Short Circuit Current Isc 6 07 6 03 5 94 5 89 Cell Type Silicon hetero junction Silicon hetero junction Silicon hetero junction Silicon hetero junction Maximum System Voltage 600 600 600 600 Factory Installed Bypass Diodes 4 4 4 4 Maximum series fuse A 15 15 15 15 Silicon hetero junction Monocrysttaline silicon amorphous silicon hetero junction Mechanical Specifications Length mm i...

Страница 5: ...locking sleeve needs to be used with all connectors that are exposed The locking sleeve PV SSH4 is made by STAUBLI and can only be released with a special tool also made by STAUBLI PV MS Locking sleeves are not supplied with mod ules and must be purchased sepa rately BYPASS DIODE When the modules in series strings are shaded partially it may cause reverse voltage across cells or mod ules because t...

Страница 6: ... with salt water 3 Heavy snow falls areas 4 Sand and dust damage is excessive at the installation place Heavy dirt areas by sand or dust e g desert a quarry etc 5 Installation in places where there is a concern about deterioration of panel such as heavy air pollution chemically active vapors acid rain and or soot ammonia gas etc UNPACKING AND HANDLING Do not hit the back sheet of a mod ule by the ...

Страница 7: ... structure rail Recommendation of bolt torque 10 ft lbs Figure 5 shows that a module should be attached on a mount or support structure rail by corrosive resistant metal clamps Appropriate material should be used for mounting hardware the module frame mounting structure and hardware to prevent itself from corrosion Panasonic does not provide a war ranty for clamps The module war ranty Panasonic pr...

Страница 8: ... for off grid or battery charging systems because of their operating voltage Therefore it is not recommended to use them for off grid or charging batteries without using MPPT Maximum Power Point Tracking controller These modules contain factory in stalled bypass diodes If these mod ules are incorrectly connected to each other the bypass diodes ca ble or junction box may be dam aged Do not connect ...

Страница 9: ... sistance of the grounding connec tion on the module or can even cause the grounding connection to fail entirely Corrosion can be caused by the effects of weather humidity dirt and so on It can also be caused when two dissimilar met als are in contact galvanic reac tion The module frame material is alumi num magnesium alloy All fasteners nuts bolts washers screws etc must be stainless steel unless...

Страница 10: ... washer is placed between the wire and the module frame Choose an adequate size for the cup washer and the flat washer so that the wire is fully clamped between them Note Cup washers are also called ter minal cup washers The cup washers should be stainless steel or a cup washer made of brass may be used only if a large flat washer made of stainless steel is inserted between the module frame and th...

Страница 11: ...d lock nut Tighten stainless steel set screw at the torque specified by lug manu facturer to secure copper wire The specified torque is following Ilsco Corp GBL 4DBT 10 14AWG Solid 20 in lbs 4 6AWG Strand 35 in lbs 8AWG Strand 25 in lbs 10 14AWG Strand 20 in lbs Burndy L L C CL501TN 14AWG Solid 35 in lbs 14AWG Strand 35 in lbs 4AWG Strand 45 in lbs Recommended torque value in tightening bolt and n...

Страница 12: ...ening bolt and nut is between 1 7 and 2 2 Nm Insert the wire into the wire slot Press down on both ends of the wire Manually or using channel lock pliers push the slider over the base until it covers the base This will terminate the wire For more information please refer to Instruction sheet issued by Tyco Electron ics Note Use the ground holes illustrated in Figure 6 1 Grounding Clip Assemblies T...

Страница 13: ...micro fiber cloth and ethanol Never use abrasive detergent strong alkaline detergent strong acid detergent or a detergent which forms a protective layer on the sur face of the glass to clean any part of the module The performance of a solar modules may be reduced Please be very careful since the war ranty will not cover the damages caused by detergents DISCLAIMER OF LIABILITY Panasonic does not as...

Страница 14: ...14 Edition Revision Date Revised Item Revised Content NEW Edition 2017 7 12 2nd Edition 2018 5 14 Change of format Representation of layout description sentences REVISION HISTORY ...

Отзывы: