background image

 

11 

 

Model

VBHN330SA16 VBHN325SA16

VBHN330SA16B VBHN325SA16B

Cell Number in Series

96

96

Rated Power, Watts (Pmax)

330

325

Maximum Power Voltage (Vpm)

58.0

57.6

Maximum Power Current (Ipm)

5.70

5.65

Open Circuit Voltage (Voc)

69.7

69.6

Short Circuit Current (Isc)

6.07

6.03

Cell Type

Silicon hetero-junction* Silicon hetero-junction*

Maximum System Voltage

600

600

Factory Installed Bypass Diodes  

4

4

Maximum series fuse (A)

15

15

Silicon hetero-junction*: Monocrysttaline silicon/amorphous silicon hetero-junction

Mechanical Specifications

Length, mm (inches)

Width, mm (inches)

Frame Depth, mm (inches)
Weight, kg (pounds)

Electrical Specifications

1590 (62.60)
1053 (41.46)

35 (1.38)

19 (41.89)

SPECIFICATIONS   

  

 

 

Figure 2   Dimensions 

Note) A module is installed using 4 points, symmetrical mounting within setting range (shaded). 

Fixing span must be between 1030-1230mm

 

Front 

Side 

Backside 

Dimensions in mm 

Label 

Onamba 

Junction 

Box 

Dimensions 

 (VBHNxxxSA16 and VBHNxxxSA16B) 

Mount Locations 

Содержание HIT VBHN330SA16

Страница 1: ...the Panasonic Group and is in charge of the manufacturing process for Panasonic HIT Model No VBHN330SA16 and 16B VBHN325SA16 and 16B Contents Please read before installation Safety Precautions General Information 3 Warning 3 Cautions 3 General Safety 3 UL Listing Information 3 Installation General 3 Notes on Installation 3 Operating Conditions 4 Special Conditions 5 Specifications Note on Specific...

Страница 2: ...nd the module 4th Edition 2016 11 18 Addition of figures of clamps Addition of limitation of connectors Add the figures and requirement specification of clamps Add the limitation of connectors 5th Edition 2017 3 6 Changing inscription of installation condition Addition of mounting method Change inscription of installation condition Add the mounting method of using a bolt and nut 6th Edition 2017 9...

Страница 3: ...nd causing inoperable conditions and other unknown troubles Do not insert PV cable between back side and mounting structure rail GENERAL SAFETY Follow all permissions installation and inspection requirements Before installing modules contact the appropriate authorities having jurisdiction to determine permissions installation and inspection requirements which should be followed Electrically ground...

Страница 4: ...00 224B Width Grounding mid clamp 1 16 29 5 mm End clamp 1 5 38 mm Thickness Grounding mid clamp Nominal thickness 0 11 2 85mm End clamp Nominal thickness 0 125 3 17mm Torque 9 5 N m 85 in lbs Material Grounding mid clamp 304 Stainless steel End clamp 5000 6000 Aluminum alloys Note Please refer to IronRidge manual for installation method Panasonic does not provide a warranty for clamps The module ...

Страница 5: ...ries string or each module Do not disconnect terminals while modules generate electricity and connect electrical load to avoid the hazard of electrical shock To avoid the hazard of electric shock and sparks please connect each cable after confirming the polarity of them is correct Cable conduits should be used in locations where the wiring is inaccessible to children or small animals Module Wiring...

Страница 6: ...shers see Figures 3 2 The use of cup washers is to prevent wire from slipping out from under the screw head and or the flat washer Make sure that the cup washer is placed between the wire and the module frame Choose an adequate size for the cup washer and the flat washer so that the wire is fully clamped between them Note Cup washers are also called terminal cup washers The cup washers should be s...

Страница 7: ...tion Modules are equipped with factory installed bypass diodes The factory installed diodes provide proper circuit protection for the systems within the specified system voltage so that you do not need any other additional bypass diodes MAINTENANCE Some maintenance is recommended to maintain optimal output performance of the solar modules It is also recommended to inspect the electrical and mechan...

Страница 8: ... by additional suffixes may be followed by suffix numbers and letters PV PLS S PV PLS B may be followed by suffix numbers and letters may be followed by suffix numbers and letters Male PV connectors PV KST4 EVO2 2 5 6 or 10 followed by I II III or IV followed by UR Female PV connectors PV KBT4 EVO2 2 5 6 or 10 followed by I II III or IV followed by UR PV AZS4 male PV AZB4 female http www multi con...

Страница 9: ...ore than 0 78 20 mm If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter Cup washer Terminal cup Stainless steel or brass Star washer Stainless steel Flat washer Stainless steel Flat washer Stainless steel Spring washer Stainless steel Bolt Stainless steel 8 10 M5 Grounding hole ...

Страница 10: ...e Longer side Grounding hole 0 205 diameter 5 2mm Grounding Clip 8 32 Screw Stainless steel Nut Stainless steel Copper wire Length not less than 0 63 16 mm not more than 0 78 20 mm Figure 1 2 Installation Solar Module Module Mounting Structure Rail 5 16 or M8 Bolt Stainless steel 5 16 or M8 Nut Stainless steel Flat washer Stainless steel Flat washer Stainless steel Spring washer Stainless steel ...

Страница 11: ...ass Diodes 4 4 Maximum series fuse A 15 15 Silicon hetero junction Monocrysttaline silicon amorphous silicon hetero junction Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds Electrical Specifications 1590 62 60 1053 41 46 35 1 38 19 41 89 SPECIFICATIONS Figure 2 Dimensions Note A module is installed using 4 points symmetrical mounting within setting...

Отзывы: