may contribute to fire hazards.  Additional devices such as 
ground fault, fuses, and disconnects may be required.  

  Do not use modules of different specifications in the same 

system.  

  Follow all safety precautions of other system components 

which are used. 

 

UL Listing Information 

To satisfy UL requirements, when installing the modules, be sure 
to:  
1)  Use only stranded or solid copper single–conductor sunlight-

resistant cable rated for outdoor use (e.g. type UF or USE) , 
for all wiring that is exposed to weather. 

2)  Observe the requirements described in sections labeled 

INSTALLATION and SPECIFICATIONS. 

 

INSTALLATION 
General 

Please read this guide completely before  installing or using your 
Panasonic PV modules. This section contains important electrical 
and mechanical specifications.. 

 

Modules should be firmly fixed in place in a manner suitable to 
withstand all expected loads, including wind and snow loads.  

  Metals used in locations that are exposed to moisture shall 

not be employed alone or in combinations that could result in 
deterioration or corrosion. 

 

Install modules where they are not shaded by obstacles like 
buildings and trees.  Pay special attention to avoid partially 
shading the modules by objects during the daytime.  

  If needed, contact an Authorized Representative 

with questions regarding mounting profiles for 
Panasonic modules. 

 

Notes on Installation  

  Clearance between the roof surface and module 

frame is required to allow cooling air to circulate 
around the back of the module. This also allows 
any condensation or moisture to dissipate.  Install 
modules with a minimum of 1 inch clearance 
between the roof surface and the modules so that 
air can circulate. 

  SANYO recommends the installation method and 

mounting profile shown in Figure 1  

 

A module should be attached on a mount or 
support structure rail by corrosive-resistant 
metal clamps.

 

 

The clamps should be made of aluminum 
alloy or  other material  that will reasonably  
protect against the a risk of electrolytic 
corrosion.  

 

  Recommendation of bolt torque range: 16N.m to 

20N.m

 

 

 

The module was tested using Unirac clamps 
with the specifications below; if a different 
clamp is used it must have a design load 
capacity equivalent to or greater than the load 
specified in this Manual.

 

¾

  Provider: UniRac, Inc. 

¾

  Part number: SolarMount®   

¾

  Clamps type: Top Mounting  Clamps 

¾

  Clamp size:Mid clamp and End clamp, F 

size, 

¾

  Unirac Part No.320029, 320102 

¾

  Width: 1.5” (38 mm) 

¾

  Thickness :  0.12”(3 mm) 

¾

  Torque range: 16N.m to 20N. 

¾

  Material: Aluminum Alloy 

 

Sanyo  does not provide a warranty for clamps. The module 
warranty Sanyo provides  shall be voided if clamps selected 
by the customer are of an improper  material or size. 

 

Operating Conditions 

SANYO requires that modules are operated within the following 
Operating Conditions: 
1)  Terrestrial applications only—no outer space or Special 

Conditions (see below). 

2)  The ambient temperature must be within –20°C (-4°F) to 46°C 

(115°F).  The temperature limits are defined as the Monthly 
Average High or Low of the installation site.   

3)  The wind pressure load of the installation site should be less 

than 2,880N/m

2

 (60PSF)  

4)  Some environmental conditions could apply. Please refer to 

Sanyo’s warranty exclusions.

 

 

SPECIFICATIONS 
Notes on Specifications 

1)  Rated electrical characteristics are within –5% to +10% of the 

values measured at Standard Test Conditions (STC). STC 
conditions are; Irradiance of 1000W/m, 25

o

C cell temperature, 

and solar spectral irradiance per IEC 60904-3. Note: At the 

 

 

 

 

 

Installation (reference) 

Solar Module

Metal clamp B
(2 places) 

Metal clamp A
(2 places) 

Mounting 
Structure Rail

Metal clamp B 

Solar Module 

Metal clamp A

Mounting Structure Rail 

Metal clamp B 

Module 

Mounting Structure 

M8 Nut

Metal clamp A

M8 Bolt

M8 Bolt

M8 Nut

End of Module

Between Modules

Figure 1.  Installation 

38mm

38mm 

Содержание HIT Power 210A

Страница 1: ...age and injury Work only in dry conditions with dry modules and dry tools Do not stand or step on modules Do not puncture cut scratch or damage the backsheet of a module Backsheet damage will void a module s Limited Warranty and may cause fire Never use modules with a damaged back sheet Do not allow children and unauthorized persons near the installation or storage site of modules Completely groun...

Страница 2: ... Figure 1 A module should be attached on a mount or support structure rail by corrosive resistant metal clamps The clamps should be made of aluminum alloy or other material that will reasonably protect against the a risk of electrolytic corrosion Recommendation of bolt torque range 16N m to 20N m The module was tested using Unirac clamps with the specifications below if a different clamp is used i...

Страница 3: ...nect electrical load to avoid the hazard of electrical shock To avoid the hazard of electric shock and sparks please connect each cable after confirming the polarity of them is correct Cable conduits should be used in locations where the wiring is inaccessible to children or small animals Module Wiring The number of modules that can be wired in series is recommended to be ten 10 or fewer If connec...

Страница 4: ...terminal cup washers The cup washers should be stainless steel or a cup washer made of brass may be used only if a large flat washer made of stainless steel is inserted between the module frame and the cup washer Choose the adequate size for the large flat washer between the module frame and the cup washer so that the cup washer doesn t contact the module frame and is fixed stably to the module fr...

Страница 5: ...l enclosure is equipped for electrical connections Modules are equipped with MC TM plugs as a terminal enclosure Use these MC TM plugs for electrical connections Junction Box and Terminals Modules are equipped with one junction box containing terminals for both positive and negative polarity and bypass diodes Each terminal is dedicated to one polarity with the polarity symbols engraved onto the bo...

Страница 6: ... to inspect the electrical and mechanical connections annually If you need electrical or mechanical inspection or maintenance it is recommended to have a licensed authorized professional carry out the inspection or maintenance to avoid the hazards of electric shock or injury The return of any modules will not be accepted by SANYO unless prior written authorization has been given by SANYO As part o...

Страница 7: ...between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter Cup washer Terminal cup Stainless steel or brass Star washer Stainless steel Flat washer Stainless steel Flat was...

Страница 8: ...me Longer side Grounding hole 0 205 diameter 5 2mm Flat washer Stainless steel Thickness not less than 0 037 0 94 mm Diameter not less than 0 75 19 05 mm Grounding Lug Bolt Stainless steel 8 10 M5 Nut Stainless steel Copper wire Set screw Stainless screw Star washer Stainless steel Length not less than 0 63 16 mm not more than 0 78 20 mm Self tapping screw Stainless steel Copper wire Frame Longer ...

Страница 9: ...ith bolt and nut Note Use the larger ground holes illustrated in Figure 3 1 Grounding Clip Assemblies Tyco Electronics 1954381 2 Glass Backsheet Frame Longer side Grounding hole 0 205 diameter 5 2mm Grounding Clip 8 32 Screw Stainless steel Nut Stainless steel Copper wire Length not less than 0 63 16 mm not more than 0 78 20 mm Copper wire Frame Longer side Glass Backsheet Grounding hole 0 165 dia...

Страница 10: ...oc 600 600 600 600 Factory Installed Bypass Diodes 3 3 3 3 Maximum series fuse A 15 15 15 15 Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds Electrical Specifications 1580 62 2 798 31 4 46 1 8 16 35 3 SPECIFICATIONS PVU B5 0 2 600 V PVU B5 0 2 IP6 5 Figure 2 Dimensions Dimensions All HIT Power A Models VBHNxxxAA01 Label Note A module should be inst...