background image

ー 37 ー

High-Tro-Reel Installation Manual

 ● 

Do not modify the Tro-Reel HS in any way.

Otherwise, electric shock, fire or damage due to falling of equipment may occur.

 ● 

Do not use where exposure occurs. 

Otherwise, electric shock, fire or damage due to falling of equipment may occur.

 ● 

Use at ambient temperature -10 ℃ ~ 40 ℃. If you use outside this temperature range, please contact Panasonic Corporation.

 ● 

Install this product according to the construction rules in Electrical Equipment Technical Standards .

Especially for the primary side of power supply of the duct, use an adequate over-current breaker.

 ● 

Installation must be carried out correctly according to this Installation/Operation Manual included with the products. 

Improper installation may result in electric shock, fire or damage due to equipment falling.

■ 

Before assembling, be sure to read through this Operation / Installation Manual for correct assembly.

■ 

The work must be performed by a qualified engineer.

■ 

After setup

Please pass this Operation Manual / Installation Manual to the customer.

 

Installation of the High-Tro-Reel must be performed only by a licensed electrician. To prevent injury or accidents, always pay attention

to the following points.

Precautions on installation

 ● 

This product is for general indoor use only. Do not use this product for a damp place, a place where corrosive gas is generated 

or a place where cutting oil is directly splashed. 

Electric shock, fire or damage due to equipment falling may occur.

 ● 

Position the opening of a unit facing downward or sideways. If installed with the opening facing upward, a unit may produce 

sparks, causing fire, poor contact or separation of collector arms from wires.

 ● 

When damage and crack occurred in the insulating sheath of the duct, please change the duct.

Otherwise sparking may occur, causing fire, poor contact, or derailing of the trolley, etc. 

 ● 

When mounting the duct to the hanger,  stuff a duct into a hanger not to pinch a hand.

Observe may cause injury to your fingers.

 ● 

When remove the duct from the joiners, pull it out while holding the tip of the duct. so that the duct may not jump out from 

Joyner.

Observe, damage to the ducts, may cause injury.

 ● 

When filing the ends of the duct, use protective gear such as glasses.

Otherwise, your finger may be injured.

 ● 

Be sure to remove burrs using file after cutting, drilling.

Observe may cause injury to your fingers.

 ● 

Use products only within the specified rating and load capacity. 

Violation of specified ranges may cause burning or fire.

 ● 

Firmly fix this product to the material of construction and construct it.

Otherwise, fire or damage due to falling of equipment may occur.

 ● 

Construct the material of construction that installs the product firmly. 

Otherwise, damage due to falling of equipment may occur.

Warning

Caution

Tension Type

( Without CE Type ) Indoor Use Only

Amount of wear of the conductor is correct? 
Amount of wear of the conductor :0.5 mm or less

If it exceeds a threshold amount of wear, please replace the main 
conductor In case of wearing down to the replacement indication 
line at next inspection,  please replace earlier than usual.

Check the amount of wear of the collector and conductor 
of the duct, replace it if necessary.

Name

Inspecting point

Contents of inspection

Remedy






















Result Measures Inspection cycle (standard)

Once every 3
to 6 months

High-Tro-Reel
unit

End tension 
insulator

Joiner

Conductor

Unit

Unit

Insulating sheath

Coil spring

Insulator
Resin section
Cover

Connection

Cover

Check to see if there is any foreign particles adhering on 
its sliding surface or if it is seriously contaminated.

Clean with a specific purpose cleaner or waste cloth.

Adjust the coil spring length to be adequate.
When applying tension to the High-Tro-Reel unit, 
be sure to tighten the nuts on the tension bolts evenly.

Remove any protrusion (convex) on the arc scratch using a file.

Review distance between conductors at connecting section.
Review for any dislocated position on the unit. Correct if any.
Adjust the unit to be parallel.
Replace if cracked or broken sheath is found.

Retighten.
Retighten.
Replace if cracked or broken sheath is found.
Attach the cover for off or drop-out of the cover.
Correct the connection for aperture or difference in level.
Do over again the cutting and correct for serious flaw or crack.
Retighten.
Replace the cover if cracked or broken on resin is found.
Attach the cover for any off or drop-out of the cover.

Is there any ark generated protrusion 
(convex shaped) on its sliding surface?

Is the unit moving in zigzag way?
Isn

'

t the unit dislocated from the hanger?

Is the unit mounted parallel to the traveling rail?
Is there any cracked or broken?

Don't the insulated sheath and the resin part of 
collector spinning shaft  touch?

Is the coil spring length adequate?

Is there any nut (double nut) of coil spring loosen?
Is there any feed-in terminal screw loosen?
Is there any cracked or broken on resin section?
Is there any off or drop-out on the cover?
Is there any aperture or difference in level between conductors?
Is there any serious flaw or crack on the conductor surface?
Is there any fixed screw loosen?
Is there any cracked or broken on resin section?
Is there any off or drop-out on the joiner cover?

Confirm insulation resistance and contact resistance 
level according to the Government Rules in your country.

Once every 1 
to 3 months

Hanger

Collector arm

High-Tro-Reel 

Nut
Resin section

Collector
shoes

Arm

Spring pin
Spinning shaft
Spring bearing metal

Lead wire

Mount metal

Adjust its mounting dimension.

Correct to be match the centers.

Correct twisting.
Replace the arm if there is curve or variation.
Replace if chip or broken spring pin is found.
Replace if cracked or broken spinning shaft is found.
Replace the collector shoes if there is wear to replacement indication line.
If there is damage, replace the collector shoes.
If the collector shoes pulled, correct to have extra length on lead wire.

Retighten.
Replace if cracked or broken sheath is found.
Replace the collector shoes if there is wear to replacement indication line.
Remove the protrusion (convex) on the arc scratch using a file.
Remove the bur using a sand paper.
Retighten.

Is there any mounting nut loosen?
Is there any cracked or broken on resin section?
Is there any serious wear to replacement indication line.
Is there any ark generated protrusion (convex shaped)?
Is there any bur generated?
Is there any mounting bolt loosen?
Is the arm installing dimension correct?

Dislocation in left and right direction: 

±

10mm or less

Position of mount rod and sliding surface

 (movable range): 90

±

20mm

Is there any serious twisting on the mount rod?
Is there any curve or variation on the arm?
Is there any chip or broken?
Is there any cracked or broken on the spinning shaft?
Is there any wear or hole loosen on spring bearing metal?
Is there any damage on the sheath of lead wire?
Is the collector shoes pulled by the lead wire?
Are the centers of the collector arm mounted 
metal and the Hi-Tro-Reel unit matching?

Center 
feed-in joiner

Joiner
(without feed
  -in terminal)

Joints

Terminal

Cover

Is there a large gap between the tow conductors? 
Is there a significant damage and cracks on conductor surface?
Is there a loose the screws? 
Is there a loose the terminal screws ?
 
Is there a damage or cracks in the resin?
Is there a out of Joiner cover or drop out?

Fix the conductor connection section.
Re-processing terminal again, and fix
Tighten screws more.
Tighten screws more.
Replace the cover. 
Attached to the cover

Is there a loose the screws?

Tighten screws more.

○:Exchange required

Measures

●:Finished with exchange
△:Adjustment required
▲:Finished with adjustment

Result

○:Normal

×:Abnormality

A  title

Check day

  Y       D       M

The check 

person in charge

Trial run

Periodic inspection

Maintenance table

 

 Inspections item at the time of the pre-use test run(Checking at periodic inspection).

 

 For using safely, please inspect the system one month after starting regular 

operation.

 

 The inspection cycle is mentioned below. However, determine your own 

inspection cycle based on the actual operating rate and environmental condition.

 

 Items in bold: Inspection items requiring particular attention.

Notes

To Maintenance manager

Ambient temperature

during installation

Tension(N)

4508

3332

For transverse

115

70

For transverse

3136

2254

For transverse

125

75

For transverse

10℃ or  lower

11

40℃

Coil spring length,(

     

)mm

Collector arm 

support parts 

for transverse 

Are there modification of a spring (6.2mm or more 
clearance between the spring) or  rust on the spring?

Are there abnormal wear?

Deformation of the spring, if there is rust, replace

If there is abnormal wear of the arm, replace the collector arm.

Содержание High-Tro-Reel

Страница 1: ... pre use test run of equipment and do periodic inspections Otherwise electric shock fire or damage due to falling of equipment may occur When damage and crack occurred in the insulating sheath of the duct please change the duct Otherwise sparking may occur causing fire poor contact or derailing of the trolley etc This product is for general indoor use only Do not use this product for a damp place ...

Страница 2: ...hanges the Tro Reel unit High Tro Reel unit Check the coil spring length Once every 3 to 6 months Adjust to proper length Check whether there is loosening of the nut of the coil spring Once every 3 to 6 months Retighten Check whether the resin has not been damaged Once every 3 to 6 months Exchange products End tension insulator Check whether there is loosening of the fixation screw or the terminal ...

Страница 3: ...if chip or broken spring pin is found Replace if cracked or broken spinning shaft is found Replace the collector shoes if there is wear to replacement indication line If there is damage replace the collector shoes If the collector shoes pulled correct to have extra length on lead wire Retighten Replace if cracked or broken sheath is found Replace the collector shoes if there is wear to replacement...

Страница 4: ...ere corrosive gas is generated or a place where cutting oil is directly splashed Electric shock fire or damage due to equipment falling may occur Position the opening of a unit facing downward or sideways If installed with the opening facing upward a unit may produce sparks causing fire poor contact or separation of collector arms from wires When damage and crack occurred in the insulating sheath ...

Страница 5: ...nder cable On both supply and tightening of the body Collector arm Collects power during travel Able to travel at 300m min on a straight section Joiner Connects the High Tro Reel units together in long installations more then 50m Can also feed power to 60A and 90A High Tro Reel units Hanger Fixes the High Tro Reel units to a building structure at an interval of 4m or less for standard installation...

Страница 6: ...ally and pull the High Tro Reel unit out of the box Notes When installing two or more High Tro Reel lines reinforce end tension insulator brackets by increasing angle size by one step Failure to do so may cause damage due to falling of equipment Notes Make sure brackets are parallel to the line Failure to do so may cause poor connect arm contact Notes Be careful that the end of the High Tro Reel u...

Страница 7: ...ure 90 Conductor steel plate 30mm Conductor copper plate Insulating sheath Insulating sheath Top Side Bottom 30mm 12mm 83mm 4 5mm 4 5mm filing If the High Tro Reel unit is curled be sure to straighten it before cutting Any unnecessary protrusions on the conductor should be cut off Notes Narrow Short 83mm Conductor steel plate Conductor copper plate Conductor copper plate Filing recommendation The ...

Страница 8: ...rminal tightening 2mm shifted to the side theHigh Tro Reel unit To arrange like terminal plate LB Point 2 of execution and tighten temporarily the fixation screw to facilitate the insertion of the High Tro Reel unit Move the terminal plate to the direction of the arrow by 5mm Point 3 of execution Tighten terminal plate LB by the fixation screw temporarily Point 4 of execution High Tro Reel unit Wh...

Страница 9: ...and pins inserted into the side of terminal after mounting the unit We are packing in assembly Point 6 of execution The terminal plate is different depending on the power feeding Please shown Feeding power to the High Tro Reel Crimp terminal sequenceand mounting direction of the terminal plate Point 7 of execution Tighten after confirming whether the terminal plate and the end tentsion insulator a...

Страница 10: ...ane ten times to reconfirm coil spring tightening length Failure to do so may cause poor collector arm contact or separation from wires Notes under the cover hook the projection on the cover under the cover hook the projection on the cover 1 Mounted on the cover 1 Remove on the cover 1 Remove on the cover 1 Mounted on the cover 2 Mounted under cover 2 Remove under the cover 2 Remove under the cove...

Страница 11: ...er cover Steel plate High Tro Reel unit High Tro Reel unit Joiner Screw M6 12 Joiner High Tro Reel unit Joiner cover Terminal Screw M6 12 Crimp on terminal 38m Terminal plate Conductor Hex key wrench for M6 not included Screw M6 12 Joiner High Tro Reel unit Joiner cover Hex key wrench for M6 not included Terminal 60A and 90A with feed in terminal 150A and 200A without feed in terminal Conductor co...

Страница 12: ...ls shown in following the figure Terminal sequence of the center feed in joiner into the Joint part of conductors Inserting the terminal until to touches the base Failure to do so may cause fire 4 Fixation screw of the terminal must be securely tightened by hex key wrench M6 not included Tightening torque 9 3N m 11 3N m Lead in side Install the hanger in a specified position Failure as it may dera...

Страница 13: ...ith the cable fixation part by fastening band not included 3 After connection with the feeder insert the cover along the slide rib of the Joiner base Ribs inside the cover both sides are reliably caught and is based slide rib Making sure that slide the cover The cover covers the ends of the base rib connection L terminal Power wire width CVT100mm 2 less not included Crimp Terminal not included S t...

Страница 14: ...ing the leads to the load In case of horizontal installation be sure to use the Collector arm support parts for transverse with its opening facing side Otherwise poor collector arm contact or separation from wires may occur Mount the length from the center of the duct to the center of the collector arm within A size Assembly in tandem configuration Two collector arms tandem type should be used tog...

Страница 15: ...r shoes Collector spinning shaft 12 Inspection of spinning shaft support parts Please inquire Nippon Dry Slide Co Ltd 81 072 257 2221 Caution 13 Collector shoe replacement Pull up The replacement indication line is marked to collector shoes Collector shoes should be replaced when they wear down a part at least to the replacement indication line In case of wearing down to the replacement indication...

Отзывы: